MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4055/cios.2014.6.3.267

Медицинская библиотека · Clinics in orthopedic surgery · 2014

Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures.

Nho Jae-Hwi, Gong Hyun Sik, Song Cheol Ho, Wi Seung Myung, Lee Young Ho, Baek Goo Hyun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

It is not clear whether the pronator quadratus (PQ) muscle actually heals and provides a meaningful pronation force after volar plating for distal radius fractures (DRFs). We aimed to determine whether the length of the PQ muscle, which is dissected and then repaired during volar plating for a DRF, affects the forearm rotation strength and clinical outcomes.

METHODS

We examined 41 patients who requested hardware removal after volar plating. We measured the isokinetic forearm rotation strength and clinical outcomes including grip strength, wrist range of motion, and disabilities of the arm, shoulder and hand (DASH) scores at 6 months after fracture fixation. During the hardware removal surgery, which was performed at an average of 9 months (range, 8.3 to 11.5 months) after fracture fixation, we measured the PQ muscle length.

RESULTS

The average PQ muscle length was 68% of the normal muscle length, and no significant relationship was found between the PQ muscle length and the outcomes including isokinetic forearm rotation strength, grip strength, wrist range of motion, and DASH scores.

CONCLUSIONS

This study demonstrates that the length of the healed PQ muscle does not affect isokinetic forearm rotation strength and clinical outcomes after volar plating for DRFs. The results of this study support our current practice of loose repair of the PQ that is performed by most of the surgeons to prevent tendon irritation over the plate, and suggest that tight repair of the PQ is not necessary for achieving improved forearm function.

Для цитирования: Nho Jae-Hwi, Gong Hyun Sik, Song Cheol Ho, Wi Seung Myung, Lee Young Ho, Baek Goo Hyun. Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures.. Clinics in orthopedic surgery. 2014. DOI: 10.4055/cios.2014.6.3.267.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.