m+Medelevator.RU
← Поиск публикаций
Pakistan journal of pharmaceutical sciences · 2007

Spectrophotometric methods for the simultaneous analysis of meclezine hydrochloride and pyridoxine hydrochloride in bulk drug and pharmaceutical formulations.

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Arayne M Saeed, Sultana Najma, Siddiqui Farhan Ahmed, Zuberi M Hashim, Mirza Agha Zeeshan

Аннотация

Three new spectrophotometric procedures for the simultaneous determination of pyridoxine hydrochloride and meclezine hydrochloride are described. The first method depends on the application of simultaneous equation to resolve the interference due to spectral overlapping. The analytical signals were measured at 231 and 220 nm. Calibration graphs were established for 1 to 20 microGmL(-1) for pyridoxine hydrochloride and 0.5 to 10 microGmL(-1) for meclezine hydrochloride in binary mixture. In the second method, the determination of pyridoxine hydrochloride and meclezine hydrochloride was performed by measuring the absorbances at 290 and 235 nm in the simple absorbance spectra of their mixture. In third method a yellowish orange complex of pyridoxine hydrochloride was formed with ferric chloride, which absorbs in the visible region with lambda(max) at 445 nm. Calibration curve of complex formation range was conducted in between 20 to 250 microGmL(-1). These methods were validated with respect to accuracy, precision, linearity, limit of detection and quantification. Regression analysis of Beer's plot showed good correlation in a general concentration range of 1 to 20 microGml(-1) with correlation coefficient (r = 0.9999 and 0.9999; CV < 0.858) for pyridoxine hydrochloride, whereas meclezine hydrochloride concentration range 0.5 to 10 microGmL(-1) with correlation coefficient (r = 0.9998 and 0.9998; CV < 0.826). These methods can be readily applied, without any interference from the excipients. The suggested procedures were successfully applied to the determination of these compounds in synthetic mixtures and in pharmaceutical preparations, with high percentage of recovery, good accuracy and precision.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты