Automated segmentation and quantification of liver and spleen from CT images using normalized probabilistic atlases and enhancement estimation.

Linguraru Marius George, Sandberg Jesse K, Li Zhixi, Shah Furhawn, Summers Ronald M

Оценочное исследованиеСтатьяResearch Support, N.I.H., IntramuralПеревод в очереди

Аннотация

PURPOSE: To investigate the potential of the normalized probabilistic atlases and computer-aided medical image analysis to automatically segment and quantify livers and spleens for extracting imaging biomarkers (volume and height).

METHODS

A clinical tool was developed to segment livers and spleen from 257 abdominal contrast-enhanced CT studies. There were 51 normal livers, 44 normal spleens, 128 splenomegaly, 59 hepatomegaly, and 23 partial hepatectomy cases. 20 more contrast-enhanced CT scans from a public site with manual segmentations of mainly pathological livers were used to test the method. Data were acquired on a variety of scanners from different manufacturers and at varying resolution. Probabilistic atlases of livers and spleens were created using manually segmented data from ten noncontrast CT scans (five male and five female). The organ locations were modeled in the physical space and normalized to the position of an anatomical landmark, the xiphoid. The construction and exploitation of liver and spleen atlases enabled the automated quantifications of liver/spleen volumes and heights (midhepatic liver height and cephalocaudal spleen height) from abdominal CT data. The quantification was improved incrementally by a geodesic active contour, patient specific contrast-enhancement characteristics passed to an adaptive convolution, and correction for shape and location errors.

RESULTS

The livers and spleens were robustly segmented from normal and pathological cases. For the liver, the Dice/Tanimoto volume overlaps were 96.2%/92.7%, the volume/height errors were 2.2%/2.8%, the root-mean-squared error (RMSE) was 2.3 mm, and the average surface distance (ASD) was 1.2 mm. The spleen quantification led to 95.2%/91% Dice/Tanimoto overlaps, 3.3%/ 1.7% volume/height errors, 1.1 mm RMSE, and 0.7 ASD. The correlations (R2) with clinical/manual height measurements were 0.97 and 0.93 for the spleen and liver, respectively (p < 0.0001). No significant difference (p > 0.2) was found comparing interobserver and automatic-manual volume/height errors for liver and spleen.

CONCLUSIONS

The algorithm is robust to segmenting normal and enlarged spleens and livers, and in the presence of tumors and large morphological changes due to partial hepatectomy. Imaging biomarkers of the liver and spleen from automated computer-assisted tools have the potential to assist the diagnosis of abdominal disorders from routine analysis of clinical data and guide clinical management.

Для цитирования: Linguraru Marius George, Sandberg Jesse K, Li Zhixi, Shah Furhawn, Summers Ronald M. Automated segmentation and quantification of liver and spleen from CT images using normalized probabilistic atlases and enhancement estimation.. Medical physics. 2010. DOI: 10.1118/1.3284530.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.