MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bioelechem.2025.108906

Медицинская библиотека · Bioelectrochemistry (Amsterdam, Netherlands) · 2025

An electrochemical aptasensor based on bimetallic carbon nanocomposites AuPt@rGO for ultrasensitive detection of adenosine on portable potentiostat.

Gong Zheng, Zhao Hongli, Mao Yi, Zhou Fangfang, Shi Zehui, Lan Minbo

СтатьяПеревод в очереди

Аннотация

Adenosine plays a crucial role in the cardiovascular and nervous systems of living organisms. Excessive adenosine can lead to arrhythmias or heart failure, making the accurate detection of adenosine highly valuable. Given the widespread use of sensors for detecting small molecules, we propose a sensitive electrochemical aptasensor for adenosine detection in this study. The aptasensor utilized reduced graphene oxide (rGO) as the base material, and its performance was further enhanced by loading gold-platinum nanoparticles (AuPt@rGO) to improve the current response. The AuPt@rGO composite was synthesized using a simple process and was modified onto screen-printed electrodes (SPE) fabricated in the laboratory. This modification increased the effective area of the working electrode, providing more contact sites and enhancing sensitivity for adenosine detection. As a result, the sensor exhibited excellent performance in selectivity, sensitivity, and stability, with a linear response range for adenosine from 10 nM to 10 μM and a detection limit of 1.28 nM (n = 3). Furthermore, successful detection of adenosine levels in real samples was achieved using a portable potentiostat, demonstrating excellent recovery rates (95.99 %-103.4 %). These results indicate the aptasensor's significant potential for future applications in field analysis and medical diagnostics.

Для цитирования: Gong Zheng, Zhao Hongli, Mao Yi, Zhou Fangfang, Shi Zehui, Lan Minbo. An electrochemical aptasensor based on bimetallic carbon nanocomposites AuPt@rGO for ultrasensitive detection of adenosine on portable potentiostat.. Bioelectrochemistry (Amsterdam, Netherlands). 2025. DOI: 10.1016/j.bioelechem.2025.108906.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.