MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00604-025-07771-0

Медицинская библиотека · Mikrochimica acta · 2025

Advancement in continuous lactate determination in untreated human serum: multipolymer-based amperometric biosensor coupled with a low-cost 3D-printed microfluidic cell.

Sainz-Calvo Álvaro Jesús, Sierra-Padilla Alfonso, Bellido-Milla Dolores, Blanco-Díaz Lorena, Fernández-Alba Juan Jesús, González-Macías Carmen, García-Guzmán Juan José, Palacios-Santander José María, Cubillana-Aguilera Laura

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Enzyme saturation in biosensing has been established as a main hindrance in lactate monitoring due to the high concentration of this species in biological samples. In this paper, a Sonogel-carbon transducer has been used for the fabrication of an amperometric biosensor for lactate (LA) determination. The sensor was constructed by immobilizing lactate oxidase as the bioreceptor and coating the electrode surface with multipolymer layers to minimize enzyme saturation and improve operational stability. This biosensor shows adequate sensitivity (1.74 µA mM- 1 cm-2) in a linear working range from 0.2 mM to 20 mM, suitable for physiological lactate concentrations in biofluids. The response of the biosensor was studied in physiological medium using several potential interferents (glucose, uric acid, dopamine, ascorbic acid, KCl, NaCl, CaCl2 and BSA), demonstrating negligible interference from these common electroactive species. A microfluidic cell was designed and fabricated using polyethylene terephthalate glycol (PETG) through a rapid and low-cost 3D printing process. Finally, the prepared microfluidic cell was applied to lactate monitoring in flow regime using the biosensor with both synthetic and real untreated human serum samples, showing excellent correlation with two standard reference techniques and confirming its reliability. These results highlight the potential of the proposed microfluidic amperometric biosensor as a robust, real-time tool for biomedical lactate monitoring.

Для цитирования: Sainz-Calvo Álvaro Jesús, Sierra-Padilla Alfonso, Bellido-Milla Dolores, Blanco-Díaz Lorena, Fernández-Alba Juan Jesús, González-Macías Carmen, García-Guzmán Juan José, Palacios-Santander José María, Cubillana-Aguilera Laura. Advancement in continuous lactate determination in untreated human serum: multipolymer-based amperometric biosensor coupled with a low-cost 3D-printed microfluidic cell.. Mikrochimica acta. 2025. DOI: 10.1007/s00604-025-07771-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.