MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2026.108697

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2026

Robot-Assisted Microwave Ablations of Liver Tumors: Is This the Beginning of a Paradigm Shift?

Narayanan Govindarajan, Ruiz Elizabeth M, Dijkstra Madelon, van den Bemd Bente A T, Mahendra Ashwin, Ramasamy Shakthi Kumaran, Landinez Gina P, Schiro Brian J, Gandhi Ripal T, Peña Constantino S, van der Lei Susan

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the safety and accuracy of robot-assisted microwave ablation (MWA) for primary and secondary liver tumors using the Epione (Quantum Surgical, Montpellier, France) robotic system.

MATERIALS AND

METHODS

This single-center retrospective study included all computed tomography (CT)-guided robotic MWA procedures performed at the Miami Cancer Institute, Baptist Health South Florida from May 2023 to March 2025. Primary endpoints were safety, assessed by adverse events related to robotic guidance or ablation, and accuracy, defined by the need for minor (depth/lateral) or major (antenna removal and reinsertion) adjustments. Secondary endpoints included feasibility, technical success, local tumor progression (LTP), LTP-free survival (LTPFS), and local control (LC).

RESULTS

A total of 153 robot-assisted antenna placements were performed to treat 152 tumors in 78 patients. Robotic placement was feasible in 98.7% (77/78) of patients. Technical success was achieved in 96.8% (152/157) of trajectories. Among all trajectories, 18.5% (29/157) required no adjustment, 62.4% (98/157) required minor depth adjustment, 17.8% (28/157) required minor lateral adjustment, and 3.2% (5/157) required major adjustment. Of major adjustments, 4 were corrected with robotic reinsertion, and 1 was corrected manually. Mean preadjustment lateral deviation was 5.6 mm (SD ±3.9). Adverse events occurred in 14.1% (11 Grade 1, 2 Grade 2, and 1 Grade 3) of procedures, none directly related to robotic guidance. Median follow-up was 6.9 months. The 6-month LTPFS per tumor for patients treated in the first versus second year was 87.1% versus 94.9%, respectively (hazard ratio, 0.385; 95% confidence interval, 0.083-1.771; P = .220).

CONCLUSIONS

Robotic guidance for liver MWA demonstrated high feasibility, excellent technical success, and low placement error with no robot-related complications, supporting its safety and accuracy in clinical practice.

Для цитирования: Narayanan Govindarajan, Ruiz Elizabeth M, Dijkstra Madelon, van den Bemd Bente A T, Mahendra Ashwin, Ramasamy Shakthi Kumaran, Landinez Gina P, Schiro Brian J, Gandhi Ripal T, Peña Constantino S, van der Lei Susan. Robot-Assisted Microwave Ablations of Liver Tumors: Is This the Beginning of a Paradigm Shift?. Journal of vascular and interventional radiology : JVIR. 2026. DOI: 10.1016/j.jvir.2026.108697.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.