MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcct.2023.01.044

Медицинская библиотека · Journal of cardiovascular computed tomography · 2023

Appropriateness of cardiovascular computed tomography and magnetic resonance imaging in patients with conotruncal defects.

Pickard Sarah S, Armstrong Aimee K, Balasubramanian Sowmya, Buddhe Sujatha, Crum Kimberly, Kong Grace, Lang Sean M, Lee Marc V, Lopez Leo, Natarajan Shobha S, Norris Mark D, Parra David A, Parthiban Anitha, Powell Andrew J, Priromprintr Bryant, Rogers Lindsay S, Sachdeva Shagun, Shah Sanket S, Smith Clayton A, Stern Kenan W D, Xiang Yijin, Young Luciana T, Sachdeva Ritu

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To promote the rational use of cardiovascular imaging in patients with congenital heart disease, the American College of Cardiology developed Appropriate Use Criteria (AUC), but its clinical application and pre-release benchmarks have not been evaluated. We aimed to evaluate the appropriateness of indications for cardiovascular magnetic resonance (CMR) and cardiovascular computed tomography (CCT) in patients with conotruncal defects and to identify factors associated with maybe or rarely appropriate (M/R) indications.

METHODS

Twelve centers each contributed a median of 147 studies performed prior to AUC publication (01/2020) on patients with conotruncal defects. To incorporate patient characteristics and center-level effects, a hierarchical generalized linear mixed model was used.

RESULTS

Of the 1753 studies (80% CMR, and 20% CCT), 16% were rated M/R. Center M/R ranged from 4 to 39%. Infants accounted for 8.4% of studies. In multivariable analyses, patient- and study-level factors associated with M/R rating included: age <1 year (OR 1.90 [1.15-3.13]), truncus arteriosus (vs. tetralogy of Fallot, OR 2.55 [1.5-4.35]), and CCT (vs. CMR, OR 2.67 [1.87-3.83]). None of the provider- or center-level factors reached statistical significance in the multivariable model.

CONCLUSIONS

Most CMRs and CCTs ordered for the follow-up care of patients with conotruncal defects were rated appropriate. However, there was significant center-level variation in appropriateness ratings. Younger age, CCT, and truncus arteriosus were independently associated with higher odds of M/R rating. These findings could inform future quality improvement initiatives and further exploration of factors resulting in center-level variation.

Для цитирования: Pickard Sarah S, Armstrong Aimee K, Balasubramanian Sowmya, Buddhe Sujatha, Crum Kimberly, Kong Grace, Lang Sean M, Lee Marc V, Lopez Leo, Natarajan Shobha S, Norris Mark D, Parra David A, Parthiban Anitha, Powell Andrew J, Priromprintr Bryant, Rogers Lindsay S, Sachdeva Shagun, Shah Sanket S, Smith Clayton A, Stern Kenan W D, Xiang Yijin, Young Luciana T, Sachdeva Ritu. Appropriateness of cardiovascular computed tomography and magnetic resonance imaging in patients with conotruncal defects.. Journal of cardiovascular computed tomography. 2023. DOI: 10.1016/j.jcct.2023.01.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.