Histopathologic evaluation of a novel-design nitinol stent: the Biflex stent.

Verheye Stefan, De Meyer Guido, Salu Koen, Knaapen Michiel, Kockx Mark

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Optimalization and improvement in stent material, stent design and deployment may alleviate the problem of restenosis after stenting. The Biflex stent is a novel-design stent made of nitinol; the vascular response after deployment in rabbit iliac arteries was evaluated.

METHODS AND

RESULTS

Normocholesterolemic New Zealand white rabbits (n = 8) were used. Iliac arteries were randomized to receive either a stainless steel control stent or a nitinol stent and rabbits were euthanized at 30 days after implantation. All animals survived and there were no adverse events. Vessels were harvested and prepared for histopathologic analysis and histomorphometry. Stents were well opposed to the vessel wall and thrombi were absent. The lumen area and the area within the internal elastic lamina were significantly larger in the nitinol stent group as opposed to the control group (3.8 +/- 0.1 vs 3.3 +/- 0.1 mm, p = 0.009 and 4.6 +/- 0.1 vs 4.1 +/- 0.2 mm, p = 0.03, respectively). There were no differences in injury score, neointimal area, medial area, area within the external elastic lamina and amount of inflammatory cells. Staining for alpha-smooth muscle cell actin and endothelium did not show any differences between the two groups as assessed semiquantitatively.

CONCLUSION

This nitinol stent with a novel design demonstrated acceptable biocompatibility in iliac arteries of normocholesterolemic rabbits with minimal foreign-body reaction and minimal neointimal formation.

Для цитирования: Verheye Stefan, De Meyer Guido, Salu Koen, Knaapen Michiel, Kockx Mark. Histopathologic evaluation of a novel-design nitinol stent: the Biflex stent.. International journal of cardiovascular interventions. 2004. DOI: 10.1080/14628840410030342.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.