Preliminary Clinical Outcomes of an Alternating-Current-Assisted Implant Surface Decontamination Protocol: A Prospective Case Series with 12-Month Follow-Up.

Kostandini Dorian, Mattei Antonella, Falisi Giovanni, Viarchi Arianna, Gerardi Davide, Bruni Angelo, Qorri Edra, Hoz-Rodriguez Lia A, Rivera Eduardo Basañes, Rastelli Sofia, Gatto Roberto, Severino Marco, Botticelli Gianluca

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Treatment of peri-implantitis remains challenging because biofilm removal from microstructured implant surfaces is often incomplete. The present study is an uncontrolled, prospective feasibility case series involving six patients (six implants), not a controlled clinical trial, in which short-term clinical outcomes following use of a multimodal protocol to decontaminate the titanium implant surface were obtained; consequently, the independent contribution of the Ximplant® device to the observed outcomes cannot be determined. The protocol comprised surgical access, mechanical debridement, chemical conditioning, systemic administration of medication, and cleaning with an alternating-current device (Ximplant®; LED, S.p.A., Aprilia, Italy).

METHODS

Six adults with peri-implantitis, each contributing one implant, were consecutively treated using the multimodal protocol. Probing depth (PD), bleeding on probing (BOP), plaque index (PI), and suppuration (SU) were determined at baseline, 3 weeks, 6 months, and 12 months. Longitudinal changes were analyzed using repeated-measures analysis of variance and non-parametric tests for categorical variables.

RESULTS

Mean total PD decreased from 4.56 ± 0.45 mm at baseline to 3.03 ± 0.44 mm at the 3-week follow-up and remained stable at the 6-month follow-up (3.08 ± 0.35 mm) and at 12-month follow-up (3.19 ± 0.41 mm; p < 0.0001). BOP and SU were absent in all implants at each follow-up visit. PI improved markedly, although the buccal aspect of one implant was PI-positive at the 3-week and the 12-month follow-up.

CONCLUSIONS

The multimodal protocol used in this study was associated with rapid and sustained clinical improvement over the 12-month follow-up period. A study limitation is that because the individual parts of the protocol were applied concurrently, the independent contribution of any of them to the outcomes determined could not be isolated.

Для цитирования: Kostandini Dorian, Mattei Antonella, Falisi Giovanni, Viarchi Arianna, Gerardi Davide, Bruni Angelo, Qorri Edra, Hoz-Rodriguez Lia A, Rivera Eduardo Basañes, Rastelli Sofia, Gatto Roberto, Severino Marco, Botticelli Gianluca. Preliminary Clinical Outcomes of an Alternating-Current-Assisted Implant Surface Decontamination Protocol: A Prospective Case Series with 12-Month Follow-Up.. Bioengineering (Basel, Switzerland). 2026. DOI: 10.3390/bioengineering13090996.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.