MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/nau.23946

Медицинская библиотека · Neurourology and urodynamics · 2019

Mechanical impact of parturition-related strains on rat pelvic striated sphincters.

Duran Pamela, Ward Samuel, Christman Karen L, Alperin Marianna

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

AIMS: To define the operational resting sarcomere length (Ls ) of the female rat external urethral sphincter (EUS) and external anal sphincter (EAS) and to determine the mechanism of parturition-related injury of EUS and EAS using a simulated birth injury (SBI) vaginal distention model.

METHODS

EUS and EAS of 3-month-old Sprague-Dawley control and injured rats were fixed in situ, harvested, and microdissected for Ls measurements and assessment of ultrastructure. EUS and EAS function was determined at baseline, and immediately and 4 weeks after SBI, using leak point pressure (LPP) and anorectal manometry (ARM), respectively. Operational L s was compared to species-specific optimal L s using one sample Student's t test. Data (mean ± SD) were compared between groups and time points using repeated measures one-way analysis of variance, followed by Tukey's post hoc pairwise comparisons, with significance set to 0.05.

RESULTS

The operational resting Ls of both sphincters (EUS: 2.09 ± 0.07 µm, EAS: 2.02 ± 0.03 µm) was significantly shorter than optimal rat Ls of 2.4 µm. Strains imposed on EUS and EAS during SBI resulted in significant sarcomere elongation and disruption, compared with the controls (EUS: 3.09 ± 0.11 µm, EAS: 3.37 ± 0.09 µm). Paralleling structural changes, LPP and ARM measures were significantly lower immediately (LPP: 21.5 ± 1.0 cmH2 O, ARM: 5.1 ± 2.31 cmH2 O) and 4 weeks (LPP: 27.7 ± 1.3cmH2 O, ARM: 2.5 ± 1.0 cmH2 O) after SBI relative to the baseline (LPP: 43.4 ± 8.5 cmH2 O, ARM: 8.2 ± 2.0 cmH2 O); P < 0.05.

CONCLUSIONS

Analogous to humans, the short resting Ls of rat EUS and EAS favors their sphincteric function. The insult experienced by these muscles during parturition leads to sarcomere hyperelongation, myofibrillar disruption, and dysfunction of the sphincters long-term.

Для цитирования: Duran Pamela, Ward Samuel, Christman Karen L, Alperin Marianna. Mechanical impact of parturition-related strains on rat pelvic striated sphincters.. Neurourology and urodynamics. 2019. DOI: 10.1002/nau.23946.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.