[Purification feasibility of malodorous waste gas contained H2S and CS2 by DBD technique].
Аннотация
Dielectric barrier discharge(DBD) technique was applied to remove H2S and CS2 in industrial waste gas. In the research of laboratory, when the voltage between two electrodes was 12 kV, 4 x 10(3) Pa H2S was discharged in air for 5 seconds, about 100% of H2S was transformed into H2O and SO2; 1.33 x 10(3) Pa CS2 was discharged in air for 15 seconds, about 80% of CS2 was transformed into CO2, CO and SO2. When the concentration of H2S and CS2 increased, the decomposition of them decreased. Based on the results, a DBD purification apparatus which can dispose 420 m3/h, 10 m/s waste gas was designed and manufactured, the removal rate of H2S can reach 89% and the energy consumption was 5.2 W.h/m3. It was concluded that the DBD technique is worth disposing malodorous industrial waste gases contained H2S and CS2.