MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2005.06.023

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2005

Liquid-phase microextraction combined with high-performance liquid chromatography for the determination of local anaesthetics in human urine.

Ma Ming, Kang Shaoying, Zhao Qian, Chen Bo, Yao Shouzhuo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A simple liquid-phase microextraction (LPME) device combined with high-performance liquid chromatography (HPLC) is presented for the simultaneous analysis of local anaesthetics, lidocaine, bupivacaine, and tetracaine, from human urine sample. An organic solvent showed good compatibility with the mobile phase of the HPLC, o-dibutyl phthalate, was selected. Local anaesthetics are extracted from 6 ml of the feed aqueous solution and human urine sample into a water-immiscible organic solvent suspended at the needle tip of the microsyringe, then the organic solvent was directly introduced to a reversed-phase HPLC system. The kind of the organic extraction solvent, the stirring rate, the pH value of the aqueous feed solution, and the extraction time have been discussed. Under the optimized extraction conditions, high enrichment factors (more than 86.0-fold) and significant sample clean-up for all of studied local anaesthetics were achieved within 30 min. The detection limits (lower than 0.05 microg/ml) were comparable with previously reported gas chromatography methods. This method was applied to specimen of patient who was treated with extradural anaesthesia of lidocaine, bupivacaine, and tetracaine, and revealed that simultaneous determination of above three local anaesthetics in human urine was possible.

Для цитирования: Ma Ming, Kang Shaoying, Zhao Qian, Chen Bo, Yao Shouzhuo. Liquid-phase microextraction combined with high-performance liquid chromatography for the determination of local anaesthetics in human urine.. Journal of pharmaceutical and biomedical analysis. 2005. DOI: 10.1016/j.jpba.2005.06.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.