Accurate tunnel placement, graft passage, and secure suture fixation are key elements in meniscus allograft transplantation. We describe the use of a femoral distractor in meniscus transplantation. Joint distraction on the side of the transplantation by the femoral distractor can dramatically improve visibility and joint access. The distractor is applied after all necessary preparatory work. The distal femoral pin is placed in the supracondylar region on the side corresponding to the side to be transplanted. To avoid injury to the peroneal nerve, the proximal tibial pin is placed medial to lateral for both medial and lateral transplantations. The tibial pin is placed at a level approximately 1 to 2 cm below the tibial tubercle. The knee is then held in the flexion angle that affords the best visualization arthroscopically (typically between 60 degrees and 90 degrees of flexion). Gradual distraction is then applied with the distraction rod until adequate visualization is obtained. The case then proceeds with tunnel or trough creation, graft delivery, and peripheral repair. The improved visualization and access provided by the femoral distractor markedly simplifies the more challenging aspects of meniscus transplantation, helping to ensure precise tunnel placement, facilitate graft passage, and aid in accurate suturing.

Для цитирования: Kurtz Christopher A, Bonner Kevin F, Sekiya Jon K. Meniscus transplantation using the femoral distractor.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2006. DOI: 10.1016/j.arthro.2006.01.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.