MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2014.09.035

Медицинская библиотека · The Annals of thoracic surgery · 2014

Clinical outcomes of mitral valve replacement with the 16-mm ATS advanced performance valve in neonates and infants.

Moon Jiyong, Hoashi Takaya, Kagisaki Koji, Kurosaki Kenichi, Shiraishi Isao, Ichikawa Hajime

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Although mitral valve repair is the preferred treatment for mitral regurgitation in neonates and infants, mitral valve replacement (MVR) is sometimes necessary.

METHODS

From 1999 through 2013, 18 patients younger than 1 year underwent MVR with the smallest (16 mm) commercially available mechanical valve. At surgery, mean age was 4.0 ± 1.8 months (range, 4 days to 7 months), and mean body weight was 5.3 ± 1.6 kg (range, 3.2 to 8.3 kg). Prosthetic valves were implanted in the supra-annular position in 17 of the 18 patients.

RESULTS

All patients were followed up, and the mean follow-up period was 4.5 ± 3.8 years (range, 0.2 to 14 years). The rates of overall survival and freedom from redo MVR at 10 years were 88.9% and 57.8%, respectively. The causes of redo MVR were pulmonary hypertension in patients with left ventricular outflow obstruction (n = 2), hemolysis (n = 1), and a stuck valve (n = 1). The estimated effective orifice area index (effective orifice area/body surface area) was significantly inversely correlated with peak transmitral pressure gradient (r = -0.784, p < 0.01). The rate of freedom from permanent pacemaker implantation at 10 years was 71.2%. Three of the 5 pacemaker implantation procedures were for postoperative sick sinus syndrome. Although intracranial hemorrhage developed in 3 infants, all neurologic sequelae resolved.

CONCLUSIONS

The implanted valves were durable, and no premature increase in transmitral pressure gradient was observed. Complications included injury of the sinus node artery and hemorrhage related to anticoagulation therapy.

Для цитирования: Moon Jiyong, Hoashi Takaya, Kagisaki Koji, Kurosaki Kenichi, Shiraishi Isao, Ichikawa Hajime. Clinical outcomes of mitral valve replacement with the 16-mm ATS advanced performance valve in neonates and infants.. The Annals of thoracic surgery. 2014. DOI: 10.1016/j.athoracsur.2014.09.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.