MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aog.0000000000006087

Медицинская библиотека · Obstetrics and gynecology · 2025

Use of Artificial Intelligence-Based Software to Aid in the Identification of Ultrasound Findings Associated With Fetal Congenital Heart Defects.

Lam-Rachlin Jennifer, Punn Rajesh, Behera Sarina K, Geiger Miwa, Lachaud Matthias, David Nadine, Garmel Sara, Fox Nathan S, Rebarber Andrei, DeVore Greggory R, Zelop Carolyn M, Janssen Matthew K, Sylvester-Armstrong Kendra R, Kennedy John, Spiegelman Jessica, Heiligenstein Mia, Bessis Roger, Mobeen Sadia, Kia Farnaaz, Friedman Caroline, Melka Stephanie, Stos Bertrand, De Boisredon Malo, Askinazi Eric, Thorey Valentin, Gardella Christophe, Levy Marilyne, Arunamata Alisa

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To evaluate whether artificial intelligence (AI)-based software was associated with enhanced identification of eight second-trimester fetal ultrasound findings suspicious for congenital heart defects (CHDs) among obstetrician-gynecologists (ob-gyns) and maternal-fetal medicine specialists.

METHODS

A dataset of 200 fetal ultrasound examinations from 11 centers, including 100 with at least one suspicious finding, was retrospectively constituted (singleton pregnancy, 18-24 weeks of gestation, patients aged 18 years or older). Only examinations containing two-dimensional grayscale cines with interpretable four-chamber, left ventricular outflow tract, and right ventricular outflow tract standard views were included. Seven ob-gyns and seven maternal-fetal medicine specialists reviewed each examination in randomized order both with and without AI assistance and assessed the presence or absence of each finding suspicious for CHD with confidence scores. Outcomes included readers' performance in identifying the presence of any finding and each finding at the examination level, as measured by the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity. In addition, reading time and confidence were evaluated.

RESULTS

The detection of any suspicious finding significantly improved for AI-aided compared with unaided readers with a significantly higher AUROC (0.974 [95% CI, 0.957-0.990] vs 0.825 [95% CI, 0.741-0.908], P =.002), sensitivity (0.935 [95% CI, 0.892-0.978] vs 0.782 [95% CI, 0.686-0.878]), and specificity (0.970 [95% CI, 0.949-0.991] vs 0.759 [95% CI, 0.630-0.887]). AI assistance also resulted in a significant decrease in clinician interpretation time and increase in clinician confidence score (226 seconds [95% CI, 218-234] vs 274 seconds [95% CI, 265-283], P <.001; 4.63 [95% CI, 4.60-4.66] vs 3.90 [95% CI, 3.85-3.95], P <.001, respectively).

CONCLUSION

The use of AI-based software to assist clinicians was associated with enhanced identification of findings suspicious for CHD on prenatal ultrasonography.

Для цитирования: Lam-Rachlin Jennifer, Punn Rajesh, Behera Sarina K, Geiger Miwa, Lachaud Matthias, David Nadine, Garmel Sara, Fox Nathan S, Rebarber Andrei, DeVore Greggory R, Zelop Carolyn M, Janssen Matthew K, Sylvester-Armstrong Kendra R, Kennedy John, Spiegelman Jessica, Heiligenstein Mia, Bessis Roger, Mobeen Sadia, Kia Farnaaz, Friedman Caroline, Melka Stephanie, Stos Bertrand, De Boisredon Malo, Askinazi Eric, Thorey Valentin, Gardella Christophe, Levy Marilyne, Arunamata Alisa. Use of Artificial Intelligence-Based Software to Aid in the Identification of Ultrasound Findings Associated With Fetal Congenital Heart Defects.. Obstetrics and gynecology. 2025. DOI: 10.1097/aog.0000000000006087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.