Image Integration to Identify Histologic and Electroanatomic Ventricular Scar: A Clinicopathological Study Comparing 2 Image Integration Systems.

De Silva Kasun, Campbell Timothy, Bennett Richard G, Turnbull Samual, Bhaskaran Ashwin, Anderson Robert D, Davey Christopher, O'Donohue Alexandra K, Schindeler Aaron, Selvakumar Dinesh, Kotake Yasuhito, Hsu Chi-Jen, Chong James J H, Kizana Eddy, Kumar Saurabh

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Cardiac magnetic resonance (CMR) image integration technologies offer promise to guide delineation of ventricular scar and arrhythmogenic substrate; however, there are limited co-registered histological data or comparative studies of commonly used CMR segmentation tools for ventricular tachycardia (VT) ablation.

OBJECTIVES

This study sought to validate 2 commonly used vendor systems (ADAS-3D and inHEART) to integrate CMR late gadolinium enhancement to electroanatomic mapping in catheter ablation of VT.

METHODS

Five sheep underwent anteroseptal infarction with electroanatomic mapping (129 ± 12 days postinfarct). A whole heart histological model of the postinfarction scar was created. CMR was segmented by ADAS-3D and inHEART and validated with histology for 3 layers (the endocardium, intramural layer, and epicardium). A subsequent clinical validation study was performed with 5 human subjects (1 postinfarction VT, 4 nonischemic cardiomyopathy). Critical sites of VT and functional substrate (deceleration zones) were matched to ADAS-3D and inHEART scar.

RESULTS

CMR-based ADAS-3D and inHEART have comparable accuracy (>75%) with moderate agreement to identify endocardial and intramural scar compared to gold standard whole-heart histology but poorer performance (modest accuracy [60%-68%] and fair agreement in the epicardial layers). Both technologies performed poorly to identify noncompact scar. Critical sites of VT colocalize reliably with ADAS-3D and inHEART scar (88% falling within 1 scar layer). More than 80% of VT critical sites demonstrated CMR late gadolinium enhancement scar in more than 1 layer.

CONCLUSIONS

ADAS-3D and inHEART image integration provide similar characterization of scar distribution and allowed similar display of the anatomic relation of critical re-entry circuit sites detected by mapping to scar. However, limitations exist in the performance of these technologies to identify epicardial and noncompact scar.

Для цитирования: De Silva Kasun, Campbell Timothy, Bennett Richard G, Turnbull Samual, Bhaskaran Ashwin, Anderson Robert D, Davey Christopher, O'Donohue Alexandra K, Schindeler Aaron, Selvakumar Dinesh, Kotake Yasuhito, Hsu Chi-Jen, Chong James J H, Kizana Eddy, Kumar Saurabh. Image Integration to Identify Histologic and Electroanatomic Ventricular Scar: A Clinicopathological Study Comparing 2 Image Integration Systems.. JACC. Clinical electrophysiology. 2026. DOI: 10.1016/j.jacep.2025.10.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.