BACKGROUND

This study was carried out to evaluate the effectiveness of anterior plating with subsequent percutaneous iliosacral screwing for the management of unstable pelvic ring injuries.

METHODS

Nineteen patients with unstable pelvic ring injuries were included in this retrospective study. All patients were followed up for at least 1 year, and their mean age was 43 years. According to the Association for Osteosynthesis-Orthopaedic Trauma Association (AO-OTA) classification, there were 5 B2 injuries, 11 C1 injuries, and 3 C2 injuries. After anterior fixation by means of plating, an iliosacral screw fixation was carried out percutaneously using a C-arm fluoroscope.

RESULTS

All fractures healed, except for 1 case of nonunion at the pubic ramus. Radiological results showed that there were 9 anatomic, 7 nearly anatomic, 2 moderate, and 1 poor reduction. Sixteen of the 19 patients had good or excellent results for function, and all these had satisfactory (anatomic or nearly anatomic) reductions. The two moderate and 1 poor result were from an unsatisfactory reduction in a type-C injury with residual neurological signs. A screw misplacement with a neurological compromise occurred in 1 patient, but there were no adverse sequelae after its removal. The complications encountered were 2 cases of screw loosening, 2 cases of anterior metal failure, and 1 deep infection.

CONCLUSIONS

Anterior plating with subsequent percutaneous iliosacral screwing may be a useful method of treatment for unstable pelvic ring injuries, and the reduction quality and residual neurological signs were important in its functional outcome.

Для цитирования: Oh Chang-Wug, Kim Poong-Taek, Kim Joon-Woo, Min Woo-Kie, Kyuung Hee-Soo, Kim Shin-Yoon, Oh Soo-Hoon, Ihn Joo-Chul. Anterior plating and percutaneous iliosacral screwing in an unstable pelvic ring injury.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2008. DOI: 10.1007/s00776-007-1201-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.