PURPOSE: Endoluminal application of mitomycin C shows promise as a nonsurgical approach to treating recalcitrant stricture but requires precise delivery to prevent mitomycin-mediated injury to adjacent normal mucosa. We describe a novel technique that uses a microporous polytetrafluoroethylene catheter balloon to endoluminally deliver mitomycin C to the target tissue while minimizing nontarget drug application.

MATERIALS AND

METHODS

A newborn infant with proximal tracheoesophageal fistula and distal atresia underwent an uncomplicated repair. However, he developed recurrent esophageal stricture resistant to multiple attempts at pneumatic dilations. An image-guided endoluminal radiologic approach that uses microporous polytetrafluoroethylene catheter balloon was developed to precisely deliver mitomycin C to the mucosal lining of the stricture post-dilation.

RESULTS

After uncomplicated pneumatic dilation under fluoroscopic guidance, we used a microporous balloon catheter to endoluminally deliver mitomycin C topically to the mucosa at the level of stricture. Three weeks post procedure, repeat esophagram showed resolution of the stricture with unobstructed flow of contrast material to the stomach. The patient had no observable side effects from mitomycin C application.

CONCLUSION

Image-guided therapies based on balloon dilation and drug-eluting microporous balloon techniques offer a safe, precise, and comprehensive approach to the treatment of recalcitrant esophageal strictures.

Для цитирования: Heran Manraj K S, Pham Tuan H, Butterworth Sonia, Robinson Ashley. Use of a microporous polytetrafluoroethylene catheter balloon to treat refractory esophageal stricture: a novel technique for delivery of mitomycin C.. Journal of pediatric surgery. 2011. DOI: 10.1016/j.jpedsurg.2010.11.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.