MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.healun.2014.09.017

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2014

Rotary pump speed modulation for generating pulsatile flow and phasic left ventricular volume unloading in a bovine model of chronic ischemic heart failure.

Soucy Kevin G, Giridharan Guruprasad A, Choi Young, Sobieski Michael A, Monreal Gretel, Cheng Allen, Schumer Erin, Slaughter Mark S, Koenig Steven C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Rotary blood pumps operate at a constant speed (rpm) that diminishes vascular pulsatility and variation in ventricular end-systolic and end-diastolic volumes, which may contribute to adverse events, including aortic insufficiency and gastrointestinal bleeding. In this study, pump speed modulation algorithms for generating pulsatility and variation in ventricular end-systolic and end-diastolic volumes were investigated in an ischemic heart failure (IHF) bovine model (n = 10) using a clinically implanted centrifugal-flow left ventricular assist device (LVAD).

METHODS

Hemodynamic and hematologic measurements were recorded during IHF baseline, constant pumps speeds, and asynchronous (19-60 cycles/min) and synchronous (copulse and counterpulse) pump speed modulation profiles using low relative pulse speed (±25%) of 3,200 ± 800 rpm and high relative pulse speed (±38%) of 2,900 ± 1,100 rpm. End-organ perfusion, hemodynamics, and pump parameters were measured to characterize pulsatility, myocardial workload, and LVAD performance for each speed modulation profile.

RESULTS

Speed modulation profiles augmented aortic pulse pressure, surplus hemodynamic energy, and end-organ perfusion (p < 0.01) compared with operation at constant speed. Left ventricular external work and myocardial oxygen consumption were significantly reduced compared with IHF baseline (p < 0.01) but at the expense of higher LVAD power consumption.

CONCLUSIONS

Pump speed modulation increases pulsatility and improves cardiac function and end-organ perfusion, but the asynchronous mode provides the technologic advantage of sensorless control. Investigation of asynchronous pump speed modulation during long-term support is warranted to test the hypothesis that operating an LVAD with speed modulation will minimize adverse events in patients supported by an LVAD that may be associated with long-term operation at a constant pump speed.

Для цитирования: Soucy Kevin G, Giridharan Guruprasad A, Choi Young, Sobieski Michael A, Monreal Gretel, Cheng Allen, Schumer Erin, Slaughter Mark S, Koenig Steven C. Rotary pump speed modulation for generating pulsatile flow and phasic left ventricular volume unloading in a bovine model of chronic ischemic heart failure.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2014. DOI: 10.1016/j.healun.2014.09.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.