MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.2271011658

Медицинская библиотека · Radiology · 2003

Obstetric MR pelvimetry: reference values and evaluation of inter- and intraobserver error and intraindividual variability.

Keller Thomas M, Rake Annett, Michel Sven C A, Seifert Burkhardt, Efe Gul, Treiber Karl, Huch Renate, Marincek Borut, Kubik-Huch Rahel A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To establish obstetric magnetic resonance (MR) pelvimetric reference values in a large study population and stratify them according to delivery modality and to determine the intra- and interobserver error and intraindividual variability of MR pelvimetric assessment in volunteers.

MATERIALS AND

METHODS

MR pelvimetric data were retrospectively reviewed in 781 women (mean age, 28.9 years +/- 5.2 [SD]) clinically referred, and the data were correlated to obstetric history to derive normative values. Five observers assessed results of multiple MR pelvimetric examinations in 10 female volunteers (mean age, 34.7 years +/- 6.0; eight nullipara, two primipara) to provide data for measurement error analysis.

RESULTS

All values were higher in the spontaneous vaginal delivery subgroup (n = 100) and lower in the cesarean section or vacuum extraction subgroup (n = 130; intersubgroup difference, P <.001, Mann-Whitney U test). Pelvimetric parameters in the group undergoing spontaneous vaginal delivery were as follows: obstetric conjugate, 121.7 mm +/- 8.6; interspinous distance, 112.3 mm +/- 7.9; intertuberous distance, 120.6 mm +/- 11.3; transverse diameter, 129.5 mm +/- 8.7; and sagittal outlet, 115.8 mm +/- 9.9. In the volunteer study, intraobserver, interobserver, and intraindividual reliabilities were high for the obstetric conjugate (0.94-0.96), interspinous distance (0.92-0.95), and transverse diameter (0.95-0.98) but low for intertuberous distance (0.64-0.87) and sagittal outlet (0.66-0.85).

CONCLUSION

Pelvimetric dimensions are smaller in women undergoing cesarean section or vacuum extraction than they are in those delivering vaginally. The pelvimetric parameters associated with the largest measurement errors are intertuberous distance and sagittal outlet.

Для цитирования: Keller Thomas M, Rake Annett, Michel Sven C A, Seifert Burkhardt, Efe Gul, Treiber Karl, Huch Renate, Marincek Borut, Kubik-Huch Rahel A. Obstetric MR pelvimetry: reference values and evaluation of inter- and intraobserver error and intraindividual variability.. Radiology. 2003. DOI: 10.1148/radiol.2271011658.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.