MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejechocard/jen196

Медицинская библиотека · European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology · 2008

Baffle puncture guided by transoesophageal echocardiography in a patient with dextrocardia and Mustard correction.

Schwagten B, Jordaens L, Jessurun E, Witsenburg M, Scheffer M, Szili-Torok T

Клинический случайСтатьяПеревод в очереди

Аннотация

A baffle puncture is a challenging procedure but can be safely done using direct visualization of the region of interest. To our knowledge, however, it has never been performed in a patient with dextrocardia. We present a 62-year-old male with dextrocardia, right isomerism, congenitally corrected transposition of the great arteries, persistent left-sided superior and inferior caval veins, atrial septum defect, and pulmonary valve stenosis. The atrial septum defect was surgically closed with a Teflon patch, a variant Mustard operation was performed, and also a prosthetic tricuspid valve was implanted. The patient developed multiple episodes of atrial tachycardia leading to acute heart failure on many occasions. An electrophysiological study was undertaken in order to create a bi-atrial electro-anatomical map. Owing to the presence of a prosthetic tricuspid valve, the femoral venous access was used and a baffle puncture was performed using continuous monitoring with fluoroscopy and transoesophageal echocardiography (TEE). The baffle puncture was successful and the tachycardia was ablated in the systemic venous atrium. To our knowledge, we present the very first case report demonstrating a successful baffle puncture in a patient with dextrocardia and Mustard correction. Direct imaging using TEE seems to be a very useful tool for guiding the puncture.

Для цитирования: Schwagten B, Jordaens L, Jessurun E, Witsenburg M, Scheffer M, Szili-Torok T. Baffle puncture guided by transoesophageal echocardiography in a patient with dextrocardia and Mustard correction.. European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology. 2008. DOI: 10.1093/ejechocard/jen196.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.