MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0003-4975(99)00233-7

Медицинская библиотека · The Annals of thoracic surgery · 1999

Different approaches for minimally invasive closure of atrial septal defects.

Cremer J T, Böning A, Anssar M B, Kim P Y, Pethig K, Harringer W, Haverich A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To improve the acceptance of cosmetic results after closure of atrial septal defects, anterior or lateral thoracotomies are preferred rather than median sternotomies. Along with the availability of minimally invasive techniques, a further reduction in incision length appeared feasible while preserving thoracic stability.

METHODS

Various minimally invasive approaches differing in the type of incision and mode of cannulation have been applied under conditions of normothermic ventricular fibrillation. In technique 1 (n = 5), a right parasternal mini-incision was combined with a central aortic and bicaval cannulation. Technique 2 (n = 2) was composed of an anterior submammary mini-incision with femoral arterial and central bicaval cannulation. To optimize the surgical access, the transincisional cannulation of the superior vena cava was replaced by a percutaneous cervical cannulation (technique 3, n = 17).

RESULTS

Effective atrial septal defect closure assessed by intraoperative echocardiography was achieved in all patients. Central neurologic complications were completely absent. Besides temporary atrial fibrillation in one case, no other cardiac complications occurred. There were no cases with complicated wound healing.

CONCLUSIONS

Along with modified cannulation techniques and intraoperative echocardiography, minimally invasive techniques can be safely applied for atrial septal defect closure. Submammary incisions were highly accepted and allowed for adequate surgical exposure.

Для цитирования: Cremer J T, Böning A, Anssar M B, Kim P Y, Pethig K, Harringer W, Haverich A. Different approaches for minimally invasive closure of atrial septal defects.. The Annals of thoracic surgery. 1999. DOI: 10.1016/s0003-4975(99)00233-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.