MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2011.11.023

Медицинская библиотека · American journal of ophthalmology · 2012

Avastin doesn't blind people, people blind people.

Gonzalez Serafin, Rosenfeld Philip J, Stewart Michael W, Brown Jennifer, Murphy Steven P

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To review the appropriate preparation of bevacizumab for intravitreal injection by compounding pharmacies with specific recommendations designed to prevent microbial contamination.

DESIGN

Perspective.

METHODS

A review and discussion of compounding issues with supporting literature, clinical experience, illustrations, and expert opinion.

RESULTS

Closer examination of the events surrounding the recent clusters of infectious endophthalmitis cases occurring after the intravitreal injection of bevacizumab suggest that the vision loss is not the result of the drug or the injection technique, but rather of the compounding procedures used to prepare the syringes containing the bevacizumab. Noncompliance with recognized standards and poor aseptic technique are the most likely causes of these outbreaks. The key to preventing these catastrophic occurrences depends on the implementation of and strict adherence to United States Pharmacopoeia Chapter 797 requirements.

CONCLUSIONS

Recommendations arising from a root cause analysis of infectious endophthalmitis outbreaks should focus on the procedures used by pharmacies to compound bevacizumab. Microbial contamination of bevacizumab-containing syringes prepared from the same vial of drug can be avoided by using a single vial of bevacizumab for each eye or by following strict adherence to United States Pharmacopoeia Chapter 797 requirements when compounding a single vial of bevacizumab into multiple syringes.

Для цитирования: Gonzalez Serafin, Rosenfeld Philip J, Stewart Michael W, Brown Jennifer, Murphy Steven P. Avastin doesn't blind people, people blind people.. American journal of ophthalmology. 2012. DOI: 10.1016/j.ajo.2011.11.023.