Медицинская библиотека · Heart, lung & circulation · 2025

Percutaneous Femoral Arterial Closure Following Decannulation of Venoarterial Extracorporeal Membrane Oxygenation Using the MANTA Vascular Closure Device.

Batchelor Riley J, Diehl Arne, Vasudevan Thodur, Nanayakkara Shane, Htun Nay, Pellegrino Vincent, McGiffin David, Marasco Silvana, Hodgson Carol, Kaye David, Stub Dion, Walton Antony

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a life-saving therapy for patients with severe cardiac failure. If patients can be weaned, withdrawal and closure of the large-bore arterial access are required, which historically have been achieved through surgical closure. The MANTA vascular closure device (VCD) is a percutaneous, collagen-based plug device used following large-bore arterial access. We sought to evaluate the efficacy and safety of the MANTA VCD for percutaneous arterial closure following VA-ECMO decannulation.

METHOD: A non-randomised, open-label pilot study of patients who underwent decannulation from VA-ECMO with percutaneous closure using the MANTA VCD.

RESULTS

Eight patients presenting with cardiogenic shock (mean age 46.5±11.4 years, 37.5% female) underwent percutaneous closure following VA-ECMO decannulation using the 18 Fr MANTA VCD. The mean duration of VA-ECMO support prior to decannulation was 4.8±2.6 days, with arterial cannula sizes ranging from 15 to 19 Fr. There were two major adverse events: one patient had acute limb ischaemia due to superficial femoral artery occlusion, which was detected during percutaneous closure and treated surgically; another patient developed a femoral pseudoaneurysm and infected hematoma that subsequently required surgical repair 17 days after percutaneous closure.

CONCLUSIONS

In a centre with immediate access to vascular surgical backup, and in highly selected patients, percutaneous closure following VA-ECMO decannulation using the MANTA VCD is feasible; however, major vascular complications raise concerns regarding safety prior to its adoption as an alternative to up-front surgical closure.

Для цитирования: Batchelor Riley J, Diehl Arne, Vasudevan Thodur, Nanayakkara Shane, Htun Nay, Pellegrino Vincent, McGiffin David, Marasco Silvana, Hodgson Carol, Kaye David, Stub Dion, Walton Antony. Percutaneous Femoral Arterial Closure Following Decannulation of Venoarterial Extracorporeal Membrane Oxygenation Using the MANTA Vascular Closure Device.. Heart, lung & circulation. 2025. DOI: 10.1016/j.hlc.2025.06.006.