m+Medelevator.RU
← Поиск публикаций
Metabolomics : Official journal of the Metabolomic Society · 2026

MStargetR: a reproducible, containerised workflow for end-to-end targeted (MRM/SRM) mass spectrometry data processing in R.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Szemray Harrison, Nambiar Vimalnath, Hicks Dana, Lodge Samantha, Wist Julien, Lawler Nathan G, Whiley Luke

Аннотация

INTRODUCTION: Targeted metabolic phenotyping by liquid chromatography-tandem mass spectrometry (LC-MS/MS) relies on a fragmented toolchain of proprietary vendor formats, manual integration steps, and ad hoc quality-control (QC) scripts, introducing user- and laboratory-level variation that undermines reproducibility and confounds cross-laboratory and retrospective comparison.

OBJECTIVES: To provide an open-source, R-native workflow for targeted multiple reaction monitoring (MRM/SRM) mass spectrometry data that consolidates vendor file conversion, peak integration, and QC reporting into a single reproducible pipeline while preserving auditable, human-in-the-loop peak review.

METHODS: MStargetR builds on msConvert and Skyline through three modules: msConvertR (vendor-to-mzML conversion), PeakForgeR (peak boundary optimisation and automated peak integration executed through Skyline), and qcCheckR (normalisation, concentration calculation, signal and batch correction, and reporting). Additionally, MStargetR has a standalone correction module and a Shiny graphical user interface. Third-party tools are pinned in version-controlled Docker images (with Apptainer support for high-performance computing), and each analytical plate emits a fully populated sky document for inspection and reimport.

RESULTS: Applied to a published targeted lipidomics dataset of 128 human plasma samples targeting 1,161 lipid species, MStargetR processed all samples end-to-end, recovering all 1,161 targeted lipid features, 949 of which (81.7%) were detected and returned RSD < 30% across replicated long-term reference QCs. Analysis scaled linearly to 4,200 samples, averaging 4.1 s per sample.

CONCLUSION: MStargetR delivers automated batch processing, auditable peak review, and a documented QC layer in a single reproducible pipeline, supporting FAIR-aligned targeted metabolomics.