Three-Year Outcomes After Surgical Aortic Valve Replacement With a Bioprosthetic Valve from the Multi-Centre IMPACT Registry.

Bakhtiary Farhad, Benedikt Peter, Bonaros Nikolaos, Borger Michael, Doss Mirko, Feyrer Richard, Grünenfelder Jürg, Owais Tamer, Karimli Seymur, Lam Ka Yan, Liebold Andreas, Martens Andreas, Massoudy Parwis, Batashev Islam, Pöling Jochen, Scherner Maximilian Philipp, Strauch Justus, Thielmann Matthias, Vötsch Andreas, Walther Thomas, Weber Alberto, Wiesinger Stefan, Eden Matthias, Kammler Jürgen, Botta Beate, Trushina Nataliya, Vijayan Anjaly, Bramlage Peter, Zierer Andreas

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To investigate 3-year outcomes of surgical aortic valve replacement using the INSPIRIS RESILIA aortic valve bioprosthesis in patients with severe aortic stenosis.

METHODS

IMPACT registry is a prospective, multicentre, international registry with a 5-year follow-up. After 3 years, haemodynamic performance, all-cause mortality, and valve-related mortality were determined.

RESULTS

A total of 556 patients who underwent surgical aortic valve replacement with the INSPIRIS RESILIA aortic valve were enrolled between December 2019 and June 2021. The mean age was 63.4 ± 8.5 years, 29.0% were female, with a EuroSCORE II of 2.2 ± 2.5% and an STS score of 1.7 ± 2.2%. Hypertension (66.2%), coronary artery disease (34.7%), and diabetes (18.4%) were the most common comorbidities. A total of 49.3% of patients underwent full sternotomy, 58.3% isolated aortic valve replacement. The most commonly implanted valve sizes were 23 mm (35.4%) and 25 mm (30.9%). At 3 years, overall survival was 91.0%, freedom from valve-related mortality was 97.5%, from prosthetic endocarditis 96.0%, from stroke 91.5%, from valve-related dysfunction 98.0%, from reintervention 96.2%, from structural valve deterioration stage 2 96.8%, and from stage 3 99.4%. The mean transvalvular gradient was 11.9 mmHg at 3 years, with an indexed effective orifice area of 0.8 cm2/m2. Functional class improved from 41.2% class III or IV at baseline to 5.7% at 3 years.

CONCLUSIONS

Three-year outcomes, including survival and haemodynamic and functional status after surgical aortic valve replacement using the INSPIRIS RESILIA bioprosthetic aortic valve, were reported in a real-world patient population with severe aortic stenosis.

CLINICALTRIALS.GOV: NCT04053088.

Для цитирования: Bakhtiary Farhad, Benedikt Peter, Bonaros Nikolaos, Borger Michael, Doss Mirko, Feyrer Richard, Grünenfelder Jürg, Owais Tamer, Karimli Seymur, Lam Ka Yan, Liebold Andreas, Martens Andreas, Massoudy Parwis, Batashev Islam, Pöling Jochen, Scherner Maximilian Philipp, Strauch Justus, Thielmann Matthias, Vötsch Andreas, Walther Thomas, Weber Alberto, Wiesinger Stefan, Eden Matthias, Kammler Jürgen, Botta Beate, Trushina Nataliya, Vijayan Anjaly, Bramlage Peter, Zierer Andreas. Three-Year Outcomes After Surgical Aortic Valve Replacement With a Bioprosthetic Valve from the Multi-Centre IMPACT Registry.. Interdisciplinary cardiovascular and thoracic surgery. 2026. DOI: 10.1093/icvts/ivag056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.