MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12149-011-0480-4

Медицинская библиотека · Annals of nuclear medicine · 2011

Validation of reference tissue modelling for [11C]flumazenil positron emission tomography following head injury.

Geeraerts Thomas, Coles Jonathan P, Aigbirhio Franklin I, Pickard John D, Menon David K, Fryer Tim D, Hong Young T

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

[(11)C]Flumazenil ([(11)C]FMZ) positron emission tomography (PET) can be used as a measure of neuronal loss. The purpose of this study was to validate reference tissue kinetic modelling of [(11)C]FMZ PET within a group of patients with head injury.

METHODS

Following earlier studies, the pons was used as the reference region. PET scans were performed on 16 controls and 11 patients at least 6 months following injury, each of whom also had arterial blood sampling to provide whole blood and metabolite-corrected plasma input functions. Regional non-displaceable binding potentials (BP(ND)) were calculated from five reference tissue models and compared to BP(ND) from arterial input models. For the patients, the regions included a peri-lesional region of interest (ROI).

RESULTS

Total distribution volume of the pons was not significantly different between control and patient groups (P = 0.24). BP(ND) from all the reference tissue approaches correlated well with BP(ND) from the plasma input models for both controls (r (2) = 0.98-1.00; P < 0.001) and patients (r (2) = 0.99-1.00; P < 0.001). For the peri-lesional regions (n = 11 ROI values), the correlation was also high (r (2) = 0.91).

CONCLUSIONS

These results indicate that reference tissue modelling with the pons as the reference region is valid for [(11)C]FMZ PET in head-injured patients at 6 months following injury within both normal appearing and peri-lesional brain regions.

Для цитирования: Geeraerts Thomas, Coles Jonathan P, Aigbirhio Franklin I, Pickard John D, Menon David K, Fryer Tim D, Hong Young T. Validation of reference tissue modelling for [11C]flumazenil positron emission tomography following head injury.. Annals of nuclear medicine. 2011. DOI: 10.1007/s12149-011-0480-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.