Half-Life and Clearance of Cardiac Troponin I and Troponin T in Humans.

Kristensen Jonas Henrik, Hasselbalch Rasmus Bo, Strandkjær Nina, Jørgensen Nicoline, Østergaard Morten, Møller-Sørensen Peter Hasse, Nilsson Jens Christian, Afzal Shoaib, Kamstrup Pia Rørbæk, Dahl Morten, Bor Mustafa Vakur, Frikke-Schmidt Ruth, Jørgensen Niklas Rye, Rode Line, Holmvang Lene, Kjærgaard Jesper, Bang Lia Evi, Forman Julie, Dalhoff Kim, Jaffe Allan S, Thygesen Kristian, Bundgaard Henning, Iversen Kasper Karmark

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cardiac troponin (cTn) is key in diagnosing myocardial infarction (MI). After MI, the clinically observed half-life of cTn has been reported to be 7 to 20 hours, but this estimate reflects the combined elimination and simultaneous release of cTn from cardiomyocytes. More precise timing of myocardial injuries necessitates separation of these 2 components. We used a novel method for determination of isolated cTn elimination kinetics in humans.

METHODS

Patients with MI were included within 24 hours after revascularization and underwent plasmapheresis to obtain plasma with a high cTn concentration. After at least 3 weeks, patients returned for an autologous plasma retransfusion followed by blood sampling for 8 hours. cTn was measured with 5 different high-sensitivity cTn assays.

RESULTS

Of 25 included patients, 20 participants (mean age, 64.5 years; SD, 8.2 years; 4 women [20%]) received a retransfusion after a median of 5.8 weeks (interquartile range, 5.0-6.9 weeks) after MI. After retransfusion of a median of 620 mL (range, 180-679 mL) autologous plasma, the concentration of cTn in participants' blood increased 4 to 445 times above the upper reference level of the 5 high-sensitivity cTn assays. The median elimination half-life ranged from 134.1 minutes (95% CI, 117.8-168.0) for the Elecsys high-sensitivity cTnT assay to 239.7 minutes (95% CI, 153.7-295.1) for the Vitros high-sensitivity cTnI assay. The median clearance of cTnI ranged from 40.3 mL/min (95% CI, 32.0-44.9) to 52.7 mL/min (95% CI, 42.2-57.8). The clearance of cTnT was 77.0 mL/min (95% CI, 45.2-95.0).

CONCLUSIONS

This novel method showed that the elimination half-life of cTnI and cTnT was 5 to 16 hours shorter than previously reported. This indicates a considerably longer duration of cardiomyocyte cTn release after MI than previously thought. Improved knowledge of timing of myocardial injury may call for changes in the management of MI and other disorders with myocardial injury.

Для цитирования: Kristensen Jonas Henrik, Hasselbalch Rasmus Bo, Strandkjær Nina, Jørgensen Nicoline, Østergaard Morten, Møller-Sørensen Peter Hasse, Nilsson Jens Christian, Afzal Shoaib, Kamstrup Pia Rørbæk, Dahl Morten, Bor Mustafa Vakur, Frikke-Schmidt Ruth, Jørgensen Niklas Rye, Rode Line, Holmvang Lene, Kjærgaard Jesper, Bang Lia Evi, Forman Julie, Dalhoff Kim, Jaffe Allan S, Thygesen Kristian, Bundgaard Henning, Iversen Kasper Karmark. Half-Life and Clearance of Cardiac Troponin I and Troponin T in Humans.. Circulation. 2024. DOI: 10.1161/circulationaha.123.066565.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.