MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjoto.2020.102888

Медицинская библиотека · American journal of otolaryngology · 2021

The FEES box: A novel barrier to contain particles during aerosol-generating procedures.

Ganann Michelle G, Kitila Merertu, Patel Ravi, Brook Christopher D, Pisegna Jessica M

СтатьяПеревод в очереди

Аннотация

PURPOSE: Due to the COVID-19 pandemic, aerosol-generating procedures (AGPs) such as flexible endoscopic evaluation of swallowing (FEES) have been deemed high-risk and in some cases restricted, indicating the need for additional personal protective equipment. The aim of this study was to erect and study a protective barrier for FEES.

MATERIALS AND

METHODS

A PVC cube was constructed to fit over a patient while allowing for upright endoscopy. A plastic drape was fitted over the cube, and the protective barrier was subsequently named the "FEES Box." Three different particulate-generating tasks were carried out: sneezing, coughing, and spraying water from an atomizer bottle. Each task was completed within and without the FEES Box, and particulate was measured with a particle counter. The average particles/L detected during the three tasks, and baseline measurements, were statistically compared.

RESULTS

Without the FEES Box in place, the sneezing and spraying tasks resulted in a statistically significant increase in particles above baseline (p < 0.001 and p = 0.004, respectively); coughing particulate never reached levels significantly higher than baseline (p = 0.230). With use of the FEES Box, there was no statistically significant increase in particles above baseline in any of the three tasks.

CONCLUSION

The FEES Box effectively contained particles generated during sneezes and an atomizer spray. It would also likely mitigate coughing particulate, but coughing did not generate a significant increase in particles above baseline. Further research is warranted to test the efficacy of the FEES Box in containing particulate matter during a complete FEES procedure.

Для цитирования: Ganann Michelle G, Kitila Merertu, Patel Ravi, Brook Christopher D, Pisegna Jessica M. The FEES box: A novel barrier to contain particles during aerosol-generating procedures.. American journal of otolaryngology. 2021. DOI: 10.1016/j.amjoto.2020.102888.