[Determination of risperidone in human plasma by liquid chromatography-tandem mass spectrometry].
Аннотация
AIM: To develop and validate a liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the determination of risperidone in human plasma.
METHODS
Risperidone and the internal standard, diphenhydramine, were isolated from plasma by liquid-liquid extraction with etherdichloromethane (3:2, v/v) , then chromatographed on a Zorbax Extend-C18 column (150 mm x 4.6 mm ID, 5 microm) using a mobile phase consisted of acetonitrile-water-formic acid (40:60: 0.5, v/v), at a flow rate of 0.7 mL x min(-1). A Finnigan TSQ tandem mass spectrometer equipped with atmospheric pressure chemical ionization source was used as detector and was operated in the positive ion mode. Selected reaction monitoring (SRM) using the precursor product ion combinations of m/z 411-->191 and m/z 256-->167 were used to quantify risperidone and diphenhydramine (IS) , respectively.
RESULTS
The linear concentration range of the calibration curve for risperidone was 0.025 - 50 microg L(-1). The lower limit of quantification was 0.025 microg x L(-1). The intra- and inter-day relative standard deviation (RSD) across three validation running over the entire concentration range was less than 7.1%. The accuracy was within +/- 3.8%. Each sample was chromatographed within 2.7 min.
CONCLUSION
The method was proved to be rapid, sensitive and suitable for pharmacokinetic investigations of risperidone.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.