Pulmonary Artery Pressure-Guided Telemonitoring Reduced Pulmonary Artery Pressure but Did Not Result in Higher Doses of Guideline-Directed Medical Therapy-Observations from an Advanced Elderly German Heart Failure Cohort.
Аннотация
Introduction
Remote pulmonary artery pressure (PAP)-guided heart failure (HF) therapy for NYHA class III patients has been shown to reduce hospitalizations and increase survival. We aimed to assess whether PAP monitoring allows for the increase in HF directed medication in an elderly German cohort of advanced HF patients already receiving clinically optimized HF medication.
Methods
We analyzed PAP and HF medication dosage, including diuretics, in 24 patients (mean age, 76 years) using implanted PAP-sensors during the first 12 months of PAP-guided HF care in an interdisciplinary HF unit.
Results
During 12 months of PAP-guided HF therapy, PAP decreased significantly (△PAP systolic−6 ± 10, △PAP diastolic−4 ± 7, △PAP mean−4 ± 8 mm Hg, p < 0.01 for all). 16% of patients had an unplanned HF hospitalization. There was no significant change over time with respect to the dosage of RAAS inhibitors (ACE-I/ARB/ARNI), Beta blockers, or MRA treatments. In contrast, the dosage of loop diuretics increased significantly (2.1 ± 0.5-fold) over time. In the comparison of a “responder” (patients with PAP and diuretic dose decline) and “non-responder” (patients with PAP and diuretic dose increase) group, there were no significant differences between any of the baseline, medication, or HF hospitalization characteristics between the two groups.
Conclusions
In elderly patients treated with clinically optimized HF medication, no further evidence-based medication increase could be achieved using PAP-guided HF care. However, by individual adjustment of diuretic dosage, a significant decline in PAP over time occurred, which could not be predicted by any of the baseline characteristics.