m+Medelevator.RU
← Поиск публикаций
European journal of anaesthesiology · 2025

Comparison of analgesia efficacy between single-orifice and multiorifice wire-reinforced catheters for labour analgesia with the dural puncture epidural technique: A double-blind randomised controlled trial.

СтатьяРандомизированное исследованиеСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zang Yu, Du Weijia, Hu Xiaobing, Fang Xin, Luo Wei, Xu Zhendong

Аннотация

BACKGROUND: No relevant clinical studies have investigated how epidural catheter design influences the transmeningeal flux of drugs.

OBJECTIVE: To compare the analgesic outcomes between single-orifice and multiorifice wire-reinforced catheters following dural puncture epidural (DPE) for labour analgesia.

DESIGN: Prospective double-blind randomised controlled study.

SETTING: Shanghai First Maternity and Infant Hospital.

PATIENTS: Between 1 September and 27 October 2024 healthy, nulliparous women with singleton pregnancies, cervical dilation of 2 to 5 cm, and requesting neuraxial analgesia were randomised to receive either a single-orifice or multiple-orifice polyurethane wire-reinforced epidural catheter as as part of the DPE technique along with a 25-G spinal needle.

INTERVENTION: Epidural analgesia was initiated following DPE with 12 ml of 0.1% ropivacaine and 0.3 μg ml -1 sufentanil injected manually in two divided doses of 6 ml. Maintenance was then provided via programmed intermittent epidural boluses of the same solution, delivered as 10 ml every 40 min at an infusion rate of 360 ml h -1 .

MAIN OUTCOME MEASURES: The primary endpoint was the time required to achieve a numeric rating scale pain score 3 or less following the initial bolus.

RESULTS: Of 136 randomised participants, 131 were included in the analysis. Adequate analgesia was achieved significantly faster with single-orifice catheters than with multiorifice catheters, hazard ratio (HR) and 95% confidence intervals (CI) = 1.72 (1.17 to 2.53), P  = 0.003. Post hoc sensitivity analysis confirmed these results, HR = 1.79 (1.19 to 2.71), P  = 0.005.The median time (95% CI) to adequate analgesia was 11.0 (10.0 to 13.0) min for single-orifice and 14.0 (12.0 to 18.0) min for multiorifice catheters ( P  = 0.003). The single-orifice group demonstrated higher rates of adequate analgesia (89.2 vs. 72.7%, P  = 0.02) and bilateral S2 sensory blockade (95.4 vs. 83.3%, P  = 0.03) at 20 min, with no significant differences in other parameters.

CONCLUSIONS: DPE using a 25-G spinal needle and with a single-orifice catheter produced a significantly faster onset of analgesia than DPE with a multiorifice catheter during labour initiation.

TRIAL REGISTRATION: Chinese Clinical Trial Registry (No: ChiCTR2400088640; Principal investigator: Yu Zang; Registration date: 22 August 2024).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты