MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0079-6123(05)52011-9

Медицинская библиотека · Progress in brain research · 2006

Control of urinary bladder function with devices: successes and failures.

Gaunt Robert A, Prochazka Arthur

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

The management of urinary tract dysfunction is crucial for the health and well-being of people with spinal cord injury. Devices, specifically catheters, play an important role in the daily regime of bladder management for most people with spinal cord injury. However, the high incidence of complications associated with the use of catheters, and the fact that the spinal segments involved in lower urinary tract control remain intact in most cord-injured people, continue to motivate research into devices that could harness the nervous system to provide greater control over lower urinary tract function. Mechanical devices discussed in this review include catheters, artificial urethral sphincters, urethral stents and intraurethral pumps. Additionally, many attempts to restore control of the lower urinary tract with electrical stimulation have been made. Stimulation sites have included: inside the bladder, bladder wall, thigh, pelvic floor, dorsal penile nerve, pelvic nerve, tibial nerve, sacral roots, sacral nerves and spinal cord. Catheters and sacral root stimulators are two techniques whose efficacy is well established. Some approaches have proven less successful and others are still in the development stage. Modifications to sacral root stimulation including posterior root stimulation, anodal blockade and high-frequency blockade as well as new techniques including intraspinal microstimulation, urethral afferent stimulation and injectable microstimulators are also discussed. No single device has yet restored the control and function of the lower urinary tract to the pre-injury state, but new techniques are bringing this possibility closer to reality.

Для цитирования: Gaunt Robert A, Prochazka Arthur. Control of urinary bladder function with devices: successes and failures.. Progress in brain research. 2006. DOI: 10.1016/s0079-6123(05)52011-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.