m+Medelevator.RU
← Поиск публикаций
Diagnostics (Basel, Switzerland) · 2026

Anatomy- and Time-Based Post-Processing with CT Perfusion-Derived Time-Vessel Maps to Reduce Incorrect Occlusion Detections in Late-Phase CT Angiography.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Martínez Mora Andrés, Mojtahedi Mahsa, de Vries Lucas, Baumgartner Michael, Kirchhoff Yannick, Zenk Maximilian, Eckstein Katharina, Kächele Jessica, Brugnara Gianluca, Bendszus Martin, Radbruch Alexander, Roos Yvo, van Zwam Wim, van Oostenbrugge Robert, Dippel Diederik W J, Emmer Bart J, Majoie Charles, Vollmuth Philipp, Sánchez Clara I, Maier-Hein Klaus H, Marquering Henk A

Аннотация

Background/Objectives: Computer-aided vessel occlusion detection for acute ischemic stroke is typically developed on early-phase CT angiography (CTA). In late-phase CTA, enhanced venous contrast can mimic arterial occlusions and lead to incorrect occlusion detections. To counteract this, we propose a constraint-based post-processing framework that leverages anatomical and temporal vascular information from CT perfusion (CTP) scans. Methods: Vascular anatomy and relative contrast-arrival times were encoded as time-vessel maps. Three complementary constraints worked on these maps to remove incorrect detections based on distance-to-vessel truncation points, contrast-arrival time, and spatial priors. Constraints were fixed on a 32-case late-phase development subset and applied to an external held-out cohort of late-phase CTA (N = 354). To enable application without CTP, an auxiliary CTA-to-time-vessel map generator was designed to estimate maps directly from CTA. Results: In the external cohort, the framework reduced incorrect occlusions per scan from 3.9 (95% CI 3.6-4.2) to 2.1 (95% CI 1.9-2.3), preserving occlusion-level sensitivity at 80% (95% CI 69-91). The patient-level AUROC was 83 for the baseline versus 88 with post-processing. Improvements were also observed in detectors exposed to late-phase CTA, where post-processing reduced incorrect occlusions per scan from 2.8 to 1.9. As only 51 occlusion-positive cases were present in the external cohort, confidence intervals were wide. Consequently, these estimates should be interpreted with caution. Conclusions: Anatomically and temporally informed post-processing reduced incorrect occlusion detections in late-phase CTA without measurable loss of sensitivity, potentially improving robustness against CTA phase changes in external institutions.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты