Real-Time Intubation and Ventilation Feedback: A Randomized Controlled Simulation Study.
Аннотация
BACKGROUNDS: This study aimed to determine the best educational application of a respiratory function monitor and a video laryngoscope.
METHODS
This study was a randomized controlled simulation-based trial, including 167 medical students. Participants had to execute ventilation and intubation maneuvers on a newborn manikin. Participants were randomized into 3 groups. In group A (no-access), the feedback devices were not visible but recording. In group B (supervisor-access), the feedback devices were visible to the supervisor only. In group C (full-access), both the participant and the supervisor had visual access.
RESULTS
The two main outcome variables were the percentage of ventilations within the tidal volume target range (4-8mL/kg) and the number of intubation attempts. Group C achieved the highest percentage of ventilations within the tidal volume target range (full-access 63.6%, supervisor-access 51.0%, no-access 31.1%, P < .001) and the lowest mask leakage (full-access 34.9%, supervisor-access 46.6%, no-access 61.6%; A to B: P < .001, A to C: P < .001, B to C: P = .003). Overall, group C achieved superior ventilation quality regarding primary and secondary outcome measures. The number of intubation attempts until success was lowest in the full-access group (full-access: 1.29, supervisor-access: 1.77, no-access: 2.43; A to B: P = .001, A to C: P < .001, B to C: P = .015).
CONCLUSIONS
Our findings confirm that direct visual access to feedback devices for supervisor and trainees alike considerably benefits outcomes and can contribute to the future of clinical education.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.