MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcdd10010001

Медицинская библиотека · Journal of cardiovascular development and disease · 2022

Impact of Persistent Iatrogenic Atrial Septal Defect following MitraClip.

Chao Chieh-Ju, Seri Amith, Abraham Bishoy, Farina Juan M, Fennelly Evelyn, Campany Megan, Pereyra Milagros, Said Ebram F, Kenyon Courtney, Fath Ayman R, Smith Sean, Buckner-Petty Skye, Rayfield Corbin A, Fortuin David, Sweeney John P, Yang Eric H, Ayoub Chadi, Eleid Mackram F, Alkhouli Mohamad, Rihal Charanjit S, Holmes David R, Pollak Peter M, El Sabbagh Abdallah, Oh Jae K, Arsanjani Reza

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Prior studies have reported conflicting results of persistent iatrogenic atrial septal defect (iASD) and its impact following a transcatheter edge-to-edge repair (TEER) procedure. This study aims to evaluate the incidence of iASD and its clinical and hemodynamic impact after a TEER.

METHODS

Consecutive patients who underwent a TEER procedure from June 2014 to September 2020 at the Mayo Clinic were identified. The presence of iASD was retrospectively identified on post-procedure transthoracic echocardiography (TTE) to group patients into an iASD+ group and an iASD- group for comparison of prognosis and cardiac function.

RESULTS

A total of 316 patients were included; the mean age was 79.1 ± 9.1 years, and 67.7% were male. Persistent iASD was diagnosed in 108 (34.2%) patients. There was no difference concerning all-cause mortality, heart failure hospitalization, and stroke/TIA between groups at follow-up (median follow-up of 9 months). Post-procedure TTE demonstrated no differences regarding right ventricle (RV) and left ventricle (LV) dimensions and function, including TAPSE (15.2 ± 4.6 vs. 15.4 ± 5.5 mm, p = 0.875), and LV ejection fraction (51.1 ± 14.0% vs. 51.3 ± 13.9%, p = 0.933). However, patients with iASD had higher RV systolic pressure (48.7 ± 14.4 vs. 45.5 ± 14.5 mmHg, p = 0.042) compared with patients without iASD.

CONCLUSION

Notwithstanding higher RV pressures, patients with persistent iASD had no hemodynamic compromise and an equal prognosis compared with those without a residual atrial defect after a TEER procedure. These findings support the mid-term safety of procedures in which an interatrial defect needs to be created and would argue against the need for interventional closure.

Для цитирования: Chao Chieh-Ju, Seri Amith, Abraham Bishoy, Farina Juan M, Fennelly Evelyn, Campany Megan, Pereyra Milagros, Said Ebram F, Kenyon Courtney, Fath Ayman R, Smith Sean, Buckner-Petty Skye, Rayfield Corbin A, Fortuin David, Sweeney John P, Yang Eric H, Ayoub Chadi, Eleid Mackram F, Alkhouli Mohamad, Rihal Charanjit S, Holmes David R, Pollak Peter M, El Sabbagh Abdallah, Oh Jae K, Arsanjani Reza. Impact of Persistent Iatrogenic Atrial Septal Defect following MitraClip.. Journal of cardiovascular development and disease. 2022. DOI: 10.3390/jcdd10010001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.