Establishing denominator-consistent Six Sigma benchmarks for venous blood specimen rejection: a multi-center retrospective quality-indicator study using 21 million specimens in Western China.

Xie Chunbao, Sun Changrui, Xiao Li, Chen Tao, Jia Fengxi, Xiong Fangkui, Wang Zehong, Zhou Yulian, Yu Hengyong, Ding Huan, Huang Yifeng, Zhan Xiaoting, Luo Guangcheng, Zeng Jiawei, Huang Yi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pre-analytical venous blood specimen rejection can delay clinical decision-making and may increase laboratory workload, yet multicenter benchmarking remains limited by inconsistent rejection definitions and denominator selection. This study aimed to support denominator-consistent benchmarking, transferable implementation, and quality monitoring across heterogeneous-resource settings.

METHODS

We conducted a retrospective quality-indicator study across 10 hospitals in Western China using routine venous blood specimen data collected from January 1, 2023, to April 30, 2024. Rejection reasons were standardized with a prespecified mapping dictionary. Center-level rejection rates, defects per million opportunities (DPMO), and Six Sigma values were calculated using monthly venous specimen volume as the primary denominator. Percentile-based benchmarks, pooled estimates, and a month-adjusted random-intercept generalized linear mixed-effects model were used to assess performance and residual between-center heterogeneity.

RESULTS

Among 21,319,200 venous specimens, 42,060 were rejected, yielding a pooled rejection rate of 0.197%. The leading standardized rejection categories were clot/aggregation, insufficient or incorrect volume, and container/tube error. Rejection patterns varied across centers and clinical settings: inpatient and emergency events were dominated by clotting and volume problems, whereas outpatient and physical examination events more often showed order, timing, or identification errors. After temporal adjustment, measurable between-center heterogeneity persisted (intraclass correlation coefficient = 0.045).

CONCLUSION

This multi-center quality-indicator study provides a reproducible, denominator-consistent framework for benchmarking venous blood specimen rejection across multiple centers. Percentile-based benchmarks and standardized reason spectra may support local implementation and transferable Six Sigma monitoring in healthcare systems with heterogeneous resources.

Для цитирования: Xie Chunbao, Sun Changrui, Xiao Li, Chen Tao, Jia Fengxi, Xiong Fangkui, Wang Zehong, Zhou Yulian, Yu Hengyong, Ding Huan, Huang Yifeng, Zhan Xiaoting, Luo Guangcheng, Zeng Jiawei, Huang Yi. Establishing denominator-consistent Six Sigma benchmarks for venous blood specimen rejection: a multi-center retrospective quality-indicator study using 21 million specimens in Western China.. Frontiers in medicine. 2026. DOI: 10.3389/fmed.2026.1878028.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.