MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jogoh.2024.102785

Медицинская библиотека · Journal of gynecology obstetrics and human reproduction · 2024

The accuracy of sonographic fetal weight in very preterm infants (≤32 weeks).

Sgayer Inshirah, Barbara Tala, Darwish Asal, Aiob Ala, Lowenstein Lior, Wolf Maya Frank, Odeh Marwan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To examine the accuracy of sonographic fetal weight to predict birthweight in very preterm infants (<32 weeks), and to compare the accuracy of estimated fetal weight (EFW) between those small for gestational age (SGA) and those appropriate for gestational age (AGA).

STUDY

DESIGN

A retrospective study was conducted of data recorded between January 2010 and March 2023. Included were women with singleton livebirths at 23+0-31+6 weeks who had an EFW within one week from delivery. Mean percentage error, mean absolute percentage error, and underestimation and overestimation rates were calculated. We compared the accuracy of EFW between SGA and AGA infants.

RESULTS

In total, 360 women were included. The mean absolute percentage error was 7.8 % (range 0 %-68.9 %); for 207 (57.5 %) infants the percentage error was within ±10 %. Overestimation error >10 % was observed in 102 (28.3 %) infants and errors >20 % in 34 (9.4 %). Among infants born in the periviable period (23+0 - 25+6 weeks; N = 56), the mean absolute percentage error was 9.8 % (range: 0 %-40.3 %); the value was within ±10 % for only 28 periviable infants (50 %) and exceeded 20 % for 16.1 %. Among SGA compared to AGA infants, the mean absolute percentage error was higher (11.1% vs. 6.6 %, p = 0.035). Overestimation error >10 % was more frequent among SGA than AGA infants (55 (49.1 %) vs. 47 (19.0 %), p < 0.001). In a multivariate logistic regression analysis, SGA status was independently associated with a higher mean percentage error (beta = 0.260, p < 0.001) and an increased risk of an error >10 % (odds ratio = 2.1, 95 % confidence interval 1.2-3.5, p = 0.008).

CONCLUSIONS

Sonographic EFW is limited in assessing very preterm infants, particularly those who are SGA or born during the periviable period. These limitations should be considered regarding impending very preterm births and concerns about abnormal fetal growth.

Для цитирования: Sgayer Inshirah, Barbara Tala, Darwish Asal, Aiob Ala, Lowenstein Lior, Wolf Maya Frank, Odeh Marwan. The accuracy of sonographic fetal weight in very preterm infants (≤32 weeks).. Journal of gynecology obstetrics and human reproduction. 2024. DOI: 10.1016/j.jogoh.2024.102785.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.