MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.86892

Медицинская библиотека · Cureus · 2025

The Novel Introduction of a Thermal Camera in the Retrieval of a Retained Rectus Sheath Catheter: A Case Study.

Awaly Mahmoud, Norton Melanie, Ahmed Doaa, Abdelbar Ahmed, Lim Jessica, Al-Karawi D, Al-Zaidi Shakir, Sayasneh Ahmad

Клинический случайСтатьяПеревод в очереди

Аннотация

Midline laparotomy remains essential in gynecological oncology, and rectus sheath catheters (RSCs) are commonly used for postoperative analgesia. We report the case of a 46-year-old woman who underwent midline laparotomy for a suspected ovarian mass, which intraoperatively revealed mucinous ascites consistent with pseudomyxoma peritonei. An RSC was placed for pain control; however, during removal, a 5 cm segment remained embedded in the subrectus sheath. Initial imaging with plain X-ray failed to detect the retained catheter, which was eventually confirmed by computed tomography (CT). Intraoperative localization attempts using C-arm fluoroscopy and palpation were unsuccessful. A novel adjunctive approach using a Flir One Pro smartphone-based thermal camera (Flir One Pro Systems, Sweden), approved by clinical governance and operated by a trained surgeon, successfully identified localized heat on the abdominal wall, corresponding to inflammation caused by the retained catheter. Guided by this finding, a 2 cm incision was made to retrieve the coiled catheter without complications. The patient recovered well and was discharged on the third postoperative day. Histopathology confirmed pseudomyxoma peritonei, and the case was referred to a colorectal multidisciplinary team. This report highlights the feasibility and clinical value of thermal imaging as a radiation-free, real-time adjunct for detecting retained surgical materials, particularly when conventional imaging fails. Thermal imaging offers portability, precision, and safety, though its broader adoption requires standardized training, validation, and further research.

Для цитирования: Awaly Mahmoud, Norton Melanie, Ahmed Doaa, Abdelbar Ahmed, Lim Jessica, Al-Karawi D, Al-Zaidi Shakir, Sayasneh Ahmad. The Novel Introduction of a Thermal Camera in the Retrieval of a Retained Rectus Sheath Catheter: A Case Study.. Cureus. 2025. DOI: 10.7759/cureus.86892.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.