MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-024-08635-6

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025

Outcome of utilizing real-time contrast medium to detect the fistulas in spinal epidural arachnoid cysts and treat with minimally invasive surgery.

Gao Wei, Jiang Qixuan, Liu Tianjian, Chen Aiqin, Jiang Xiaohang, Hu Xinben, Gu Chi, Tang Yajuan, Shen Fang, Chen Jingyin, Ying Guangyu, Zhu Yongjian

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Spinal epidural arachnoid cysts (SEACs) are rare, non-neoplastic pathologies that can cause compressive myelopathy. Preoperative identification of the exact fistula location is crucial for minimally invasive management.

METHODS

This single-center retrospective study included 27 patients with SEACs who underwent "double-needle puncture myelography" to precisely localize the fistula before minimally invasive surgery. Clinical presentations, radiological findings, and surgical outcomes were analyzed.

RESULTS

Among the 27 patients, the most common clinical complaint was sensory dysfunction (14 patients, 51.9%). Motor dysfunction, manifested as lower limb weakness, was observed in 11 patients (40.7%), while 2 patients were asymptomatic at admission. Consistency analysis between radiographic localization and intraoperative findings demonstrated that the "double-needle puncture myelography" technique accurately identified the surgical segments and laterality of all fistulas except for one patient, who required repeat radiographic localization. Minimally invasive approaches, including hemilaminectomy or mini-hemilaminectomy, were successfully performed in 26 patients (96.3%) for fistula exposure.

CONCLUSIONS

The "double-needle puncture myelography" technique allows for the swift acquisition of precise anteroposterior and lateral projection dynamic X-ray images during the procedure. As a valuable preoperative diagnostic tool, it accurately pinpoints the location of the fistula, thereby minimizing surgical trauma and preserving spinal stability.

Для цитирования: Gao Wei, Jiang Qixuan, Liu Tianjian, Chen Aiqin, Jiang Xiaohang, Hu Xinben, Gu Chi, Tang Yajuan, Shen Fang, Chen Jingyin, Ying Guangyu, Zhu Yongjian. Outcome of utilizing real-time contrast medium to detect the fistulas in spinal epidural arachnoid cysts and treat with minimally invasive surgery.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2025. DOI: 10.1007/s00586-024-08635-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.