MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2011.01.008

Медицинская библиотека · Injury · 2011

A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless design of total hip replacement.

Grammatopoulos George, Pandit Hemant, Kambouroglou Gregoris, Deakin Mark, Gundle Roger, McLardy-Smith Peter, Taylor Adrian, Murray David

СтатьяПеревод в очереди

Аннотация

Peri-prosthetic fractures (PPF) are a recognised complication following hip arthroplasty. Prosthesis design and type influence PPF pattern. Surgeons rely on classification systems, such as the Vancouver, to aid treatment planning. This study highlights a specific fracture pattern that occurs with cemented well-fixed polished, tapered, collarless (PTC) stems. We reviewed a consecutive series of 21 PPF around well fixed PTC stems. The majority of the fractures were classified pre-operatively as Vancouver B2 (14/21), but there were also B1 (6/21) and A type fractures. The B2 fractures had common radiological and intra-operative findings: a spiral fracture with extensive fragmentation of bone and cement, debonding of cement from the implant, cement fracture, and a well-fixed cement-bone interface. Reconstruction of these fractures was more difficult than suggested by the radiographs. Two of the six patients who were considered to have a Vancouver B1 fracture underwent open reduction and internal fixation (ORIF), and had treatment-related complications. Retrospective review of the radiographs showed subtle features, such as subsidence of the stem into the centraliser, that are characteristic of a B2 fracture pattern. In summary, it is important to recognise this fracture pattern around secure PTC stems in order to prevent misinterpretation of the fracture as a Vancouver B1 rather than a B2, leading to failure of treatment, and to alert the surgeon that complex reconstruction will be required because of the extensive fragmentation.

Для цитирования: Grammatopoulos George, Pandit Hemant, Kambouroglou Gregoris, Deakin Mark, Gundle Roger, McLardy-Smith Peter, Taylor Adrian, Murray David. A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless design of total hip replacement.. Injury. 2011. DOI: 10.1016/j.injury.2011.01.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.