Intraluminal penetration of the band in patients with adjustable silicone gastric banding: radiological findings.

Pretolesi F, Camerini G, Gianetta E, Marinari G M, Scopinaro N, Derchi L E

СтатьяПеревод в очереди

Аннотация

The aim of this study was to analyse radiological findings in patients surgically treated for adjustable silicone gastric banding (ASGB) for morbid obesity complicated by band penetration into the gastric lumen. We reviewed the records of four patients with surgically confirmed penetration of gastric band into the gastric lumen; three had preoperative opaque meal, one only a plain abdominal film. Vomiting was the presenting symptom in two cases, whereas others had new weight gain and loss of early satiety. Two patients had normally closed bands: radiography showed that their position had changed from previous controls and the barium meal had passed out of their lumen. Two patients had an open band. One patient had the band at the duodeno-jejunal junction, and the tube connecting the band to the subcutaneous port presented a winding course suggesting the duodenum. In the other case, both plain film and barium studies failed to demonstrate with certainty the intragastric position of the band. As ASGB is becoming widely used, radiologists need to be familiar with its appearances and its complications. Band penetration into the stomach is a serious complication which needs band removal. Patients with this problem, often with non-specific symptoms and even those who are asymptomatic, are encountered during radiographic examinations requested either for gastric problems or follow-up purposes, and have to be properly diagnosed.

Для цитирования: Pretolesi F, Camerini G, Gianetta E, Marinari G M, Scopinaro N, Derchi L E. Intraluminal penetration of the band in patients with adjustable silicone gastric banding: radiological findings.. European radiology. 2001. DOI: 10.1007/s003300000720.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.