MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.70102

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2025

Reference Ranges of Left Ventricular Global Longitudinal Strain by Contemporary Vendor-Neutral Echocardiography Software in Healthy Subjects.

Arockiam Aro Daniela, Dong Tiffany, Agrawal Ankit, Dahdah Joseph El, Haroun Elio, Majid Muhammad, Sorathia Sharmeen, Grimm Richard A, Collier Patrick, Rodriguez Leonardo, Popovic Zoran B, Griffin Brian P, Wang Tom Kai Ming

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Left ventricular global longitudinal strain (LVGLS) by speckle-tracking transthoracic echocardiography (TTE) is an established measure of left ventricular systolic function with many clinical applications. Strain software has evolved to achieve vendor-neutrality in recent developments, although there is a notable absence of external validation studies. We assessed the normal ranges and associated factors of two-dimensional LVGLS quantification by TomTec, EchoPAC, VVI, and Epsilon contemporary strain software in a healthy cross-sectional cohort.

METHODS

One hundred healthy subjects undergoing TTE during January-April 2023 at our institution were cross-sectionally recruited, 20 per age-group, 50% were female, and 50% had GE and 50% Philips scans. TomTec version 51.02 (Autostrain LV), EchoPAC version 206 (AFI-LV), VVI version (V.2.00-070730), and Epsilon (5.0.2.11295) were utilized to quantify two-dimensional LVGLS in all patients for comparative and regression analyses.

RESULTS

Means and lower limits of normal (95% confidence intervals) of LVGLS were -17.1% (-17.5%, -16.7%) and -14.7% (-15.4%, -14.0%) for TomTec; -17.8% (-18.4%, -17.2%) and -14.4% (-15.3%, -13.5%) for EchoPAC; -16.3% (-16.9%, -15.7%) and -13.0% (-13.9%, -12.1%) for VVI; and -17.0% (-17.6%, -16.4%) and -12.8% (-13.8%, -11.8%) for Epsilon. Factors significantly associated with LVGLS measurements in multivariable regression analyses with their beta-coefficients (95% CI) were female -1.36 (-2.12, -0.59), heart rate (per 10 bpm) with a coefficient of 0.38 (0.10-0.66), left ventricular ejection fraction (per 10%) -1.03 (-1.72, -0.34), and EchoPAC (vs. TomTec) -0.62 (-1.2, 0.0), VVI (vs. TomTec) 0.82 (0.23, 1.41) and Epsilon (vs. TomTec) 0.13 (-0.45, 0.72).

CONCLUSION

LVGLS measurements were feasible across all four strain software on both GE and Philips scans in this study. Reference ranges to define normal, abnormal, and borderline LVGLS values along with associated factors in healthy patients are reported to enable clinical applications.

Для цитирования: Arockiam Aro Daniela, Dong Tiffany, Agrawal Ankit, Dahdah Joseph El, Haroun Elio, Majid Muhammad, Sorathia Sharmeen, Grimm Richard A, Collier Patrick, Rodriguez Leonardo, Popovic Zoran B, Griffin Brian P, Wang Tom Kai Ming. Reference Ranges of Left Ventricular Global Longitudinal Strain by Contemporary Vendor-Neutral Echocardiography Software in Healthy Subjects.. Echocardiography (Mount Kisco, N.Y.). 2025. DOI: 10.1111/echo.70102.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.