What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
Аннотация
PURPOSE: This study aimed to specify the optimal lengths of the distal locking screws (in a female population undergoing distal radius fracture fixation with a volar locking plate) to avoid damaging the dorsal extensor tendon compartments while preserving stability.
METHODS
Twenty-five female adult patients underwent volar locking plate fixation with four 2.4 mm locking screws inserted distally. Our modified dorsal tangential fluoroscopic view (DTV) was taken perioperatively followed by postoperative CT scans to compare the accuracy in determining the distal screw lengths.
RESULTS
Our modified DTV was 88 %, 84 %, 88 %, and 76 % sensitive in detecting screw lengths in the first, second, third, and fourth distal plate holes, respectively. According to the CT scans, none of the screws were over-penetrated in the third dorsal compartment, over-penetration was found in the second and fourth dorsal compartment. The most-accurate screw lengths in the four most distal plate holes in female distal radius fracture are 14, 20, 20, and 20 mm from the radial to the ulnar aspect.
CONCLUSION
In dorsal cortex comminution, when perioperative measuring is imprecise, inserting the most-suitable distal locking screw for problematic hole and then applying our modified DTV seems to be a simpler and safer option (Tab. 3, Fig. 4, Ref. 33).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.