MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.anpede.2023.01.008

Медицинская библиотека · Anales de pediatria · 2023

The weight for length in late preterm infants assessed with bioelectrical impedance is positively associated with anthropometric variables.

Gómez Santos Elisabet, López Lorente Francisco José, Fernández Fructuoso José Ramón, Cortés Mora Pedro, Fuentes Gutiérrez Carmen, Bosch Giménez Vicente

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The fat mass (FM) is greater in late preterm than full term infants at 1 month post birth, which may be an additional risk factor for metabolic syndrome in adulthood.

OBJETIVES: To evaluate body composition (BC) in late preterm infants using bioelectrical impedance analysis (BIA) to determine which anthropometric parameters are associated with BC. Our hypothesis was that weight-for-length is associated with the length-normalized fat mass index (FMI) at 1 year of life.

MATERIALS AND

METHODS

We carried out a prospective cohort study in 2 groups: late preterm infants and full term infants. We obtained BC data by BIA. We calculated the fat mass (FM), FMI, fat-free mass (FFM) and length-normalized fat-free mass index (FFMI) at 1, 6 and 12 months of life. After, we assessed the association of the FMI with anthropometric parameters using multiple linear regression analysis.

RESULTS

The study included 97 late preterm and 47 full term infants, although at 12 months of life, the BC assessment was performed on 66 and 33 infants, respectively. Late preterm infants, compared to full term infants, had a higher FFM at 1 month (4013 vs 3524 g), a higher weight velocity at 6 months (5480 g versus 4604 g) and a lower FFM (7232 vs 7813 g) and FFMI (12.55 vs 13.26) at 12 months of life. The multivariate regression analysis showed that the weight-for-length z-core at 12 months was positively associated with the FMI at 12 months in all infants.

CONCLUSION

The weight-for-length z-score at 12 months is strongly associated with the FMI at 1 year of life. Further studies are needed to investigate whether an increment in this anthropometric parameter may modulate the risk of chronic diseases.

Для цитирования: Gómez Santos Elisabet, López Lorente Francisco José, Fernández Fructuoso José Ramón, Cortés Mora Pedro, Fuentes Gutiérrez Carmen, Bosch Giménez Vicente. The weight for length in late preterm infants assessed with bioelectrical impedance is positively associated with anthropometric variables.. Anales de pediatria. 2023. DOI: 10.1016/j.anpede.2023.01.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.