MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10620-021-06833-6

Медицинская библиотека · Digestive diseases and sciences · 2021

Acceptability and Adequacy of a Non-endoscopic Cell Collection Device for Diagnosis of Barrett's Esophagus: Lessons Learned.

Shaheen Nicholas J, Komanduri Srinadh, Muthusamy V Raman, Wani Sachin, O'Donovan Maria, Kaushal Rajinder, Haydek John M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Endoscopic screening for Barrett's esophagus (BE) is common, costly, and underperformed in at-risk people. A non-endoscopic cell collection device can be used to collect esophageal cells, enabling BE screening.

AIMS: This study assessed the acceptability and adequacy of a commercial non-endoscopic cell collection device in a US population.

METHODS

Six sites enrolled patients with confirmed BE or heartburn/regurgitation for ≥ 6 months. Patients underwent administration of the device, consisting of a sponge encapsulated in a capsule. The capsule dwelled in the stomach for 7.5 min and was retracted via an attached suture. An adequate sample was ≥ 1 columnar cell by H&E staining. Sample quality was rated using a 0-5 scale, with 0 = no columnar cells and 5 = plentiful groups. Trefoil Factor 3 (TFF3) staining was performed. Accuracy was assessed using esophagogastroduodenoscopy (EGD)/biopsy as the gold standard.

RESULTS

Of 191 patients, 99.5% successfully swallowed the device. Overall sample adequacy was 91% (171/188), with 84% (158/188) high quality. The detachment rate was 2/190 (1%). Overall sensitivity, specificity, and accuracy of the assay with TFF3 staining were 76%, 77%, and 76%. Sensitivity, specificity, and accuracy for ≥ 3 cm BE were 86%, 77%, and 82%. Asked if willing to repeat the procedure, 93% would, and 65% indicated a preference for the device over EGD.

CONCLUSIONS

This study demonstrated a high rate of sample adequacy and promising acceptability of this non-endoscopic sampling device in a US population. Diagnostic characteristics suggest that non-endoscopic assessment of BE deserves further development as an alternative to endoscopy.

Для цитирования: Shaheen Nicholas J, Komanduri Srinadh, Muthusamy V Raman, Wani Sachin, O'Donovan Maria, Kaushal Rajinder, Haydek John M. Acceptability and Adequacy of a Non-endoscopic Cell Collection Device for Diagnosis of Barrett's Esophagus: Lessons Learned.. Digestive diseases and sciences. 2021. DOI: 10.1007/s10620-021-06833-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.