MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archsurg.137.4.452

Медицинская библиотека · Archives of surgery (Chicago, Ill. : 1960) · 2002

The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid surgery: initial experience with more than 300 cases.

Eltzschig Holger K, Posner Matthew, Moore Francis D

СтатьяПеревод в очереди

Аннотация

HYPOTHESIS: An inexpensive and widely applicable technique to monitor recurrent laryngeal nerve (RLN) function during thyroid surgery can be safely implemented.

DESIGN

Consecutive sample.

SETTING

Single-surgeon academic practice.

PATIENTS: Three hundred sixty-three consecutive patients undergoing surgery for thyroid disease in the 18 months from November 1, 1999, to May 31, 2001.

INTERVENTIONS: Anesthetic management using laryngeal mask airway and spontaneous ventilation, combined with electrical RLN stimulation and fiberoptic video laryngoscopy to confirm vocal cord response.

MAIN OUTCOME MEASURES: Vocal cord response to RLN stimulation, intraoperative anatomic findings, postoperative voice quality, and anesthetic complications.

RESULTS

We used the laryngeal mask airway-based technique in 327 cases. Visualization of vocal cords was maintained throughout the surgery in 310 cases (95%). In 10 cases (3%), the branch of the RLN carrying vocal cord function could not be identified until electrical testing was performed. A single inadvertent RLN palsy was seen in 1 of the 17 cases in which vocal cord visualization was lost during the procedure (0.03% overall). Upper airway obstruction occurred in 16 (5%) of 327 attempted procedures, requiring tracheal intubation in 3 (1%). No further complications regarding airway management were seen. Pneumothorax was observed in 5 cases (2%), each of which resolved without chest tube placement.

CONCLUSIONS

This technique can be applied to thyroid surgery as a safe means of managing the airway. It is associated with an ability to test RLN function at will in more than 95% of cases using readily available equipment.

Для цитирования: Eltzschig Holger K, Posner Matthew, Moore Francis D. The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid surgery: initial experience with more than 300 cases.. Archives of surgery (Chicago, Ill. : 1960). 2002. DOI: 10.1001/archsurg.137.4.452.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.