Expert-level segmentation using deep learning for volumetry of polycystic kidney and liver.

Shin Tae Young, Kim Hyunsuk, Lee Joong Hyup, Choi Jong Suk, Min Hyun Seok, Cho Hyungjoo, Kim Kyungwook, Kang Geon, Kim Jungkyu, Yoon Sieun, Park Hyungyu, Hwang Yeong Uk, Kim Hyo Jin, Han Miyeun, Bae Eunjin, Yoon Jong Woo, Rha Koon Ho, Lee Yong Seong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Volumetry is used in polycystic kidney and liver diseases (PKLDs), including autosomal dominant polycystic kidney disease (ADPKD), to assess disease progression and drug efficiency. However, since no rapid and accurate method for volumetry has been developed, volumetry has not yet been established in clinical practice, hindering the development of therapies for PKLD. This study presents an artificial intelligence (AI)-based volumetry method for PKLD.

MATERIALS AND

METHODS

The performance of AI was first evaluated in comparison with ground-truth (GT). We trained a V-net-based convolutional neural network on 175 ADPKD computed tomography (CT) segmentations, which served as the GT and were agreed upon by 3 experts using images from 214 patients analyzed with volumetry. The dice similarity coefficient (DSC), interobserver correlation coefficient (ICC), and Bland-Altman plots of 39 GT and AI segmentations in the validation set were compared. Next, the performance of AI on the segmentation of 50 random CT images was compared with that of 11 PKLD specialists based on the resulting DSC and ICC.

RESULTS

The DSC and ICC of the AI were 0.961 and 0.999729, respectively. The error rate was within 3% for approximately 95% of the CT scans (error<1%, 46.2%; 1%≤error<3%, 48.7%). Compared with the specialists, AI showed moderate performance. Furthermore, an outlier in our results confirmed that even PKLD specialists can make mistakes in volumetry.

CONCLUSIONS

PKLD volumetry using AI was fast and accurate. AI performed comparably to human specialists, suggesting its use may be practical in clinical settings.

Для цитирования: Shin Tae Young, Kim Hyunsuk, Lee Joong Hyup, Choi Jong Suk, Min Hyun Seok, Cho Hyungjoo, Kim Kyungwook, Kang Geon, Kim Jungkyu, Yoon Sieun, Park Hyungyu, Hwang Yeong Uk, Kim Hyo Jin, Han Miyeun, Bae Eunjin, Yoon Jong Woo, Rha Koon Ho, Lee Yong Seong. Expert-level segmentation using deep learning for volumetry of polycystic kidney and liver.. Investigative and clinical urology. 2020. DOI: 10.4111/icu.20200086.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.