MedElevator Войти в исследования
← Поиск публикаций

DOI 10.37616/2212-5043.1457

Медицинская библиотека · Journal of the Saudi Heart Association · 2025

Ultrasound Evaluation of Left Ventricular Function in Coronary Artery Ectasia: The Added Value of 2D Speckle-tracking Echocardiography.

Elshaer Osama A, Gomaa Mahmoud, Elgamal Ramy M, Fahmy Mohamed S, Dawoud Reda N, Biomy Reda, Ahmed Ahmed M, Salama Mohamed K

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the feasibility and early outcomes of totally endoscopic non-robotic mitral valve replacement using a double-port DCT approach with posterior subvalvular preservation.

METHODS

In this single-center retrospective observational study, 76 consecutive patients underwent totally endoscopic non-robotic mitral valve replacement between November 2023 and December 2025. The DCT approach was defined by exclusive endoscopic visualization, no rib spreading, a camera port and prosthesis-sized working incision placed in the same intercostal space, and thoracoscopic intracardiac instrumentation. Posterior ventricular-annular continuity was preserved whenever feasible by posterior leaflet preservation, native chordal preservation, or artificial chordal reimplantation after leaflet resection. Outcomes were reported descriptively with 95% confidence intervals.

RESULTS

Mechanical prostheses were implanted in 46 patients (60.5%) and bioprostheses in 30 (39.5%). Mean skin incision length was 3.8 ± 0.5 cm. Mean cardiopulmonary bypass and aortic cross-clamp times were 148.3 ± 38.6 and 101.9 ± 32.0 minutes, respectively. There was 1 early non-cardiac death (1.3%; 95% CI, 0.03%-7.1%), no late death, and no mitral valve reoperation (0%; 95% CI, 0%-4.7%). No moderate or severe paravalvular regurgitation was observed during early echocardiographic follow-up. Mean follow-up was 9.7 ± 6.0 months. Freedom from prosthetic valve-related adverse events was 98.6% (95% CI, 90.6%-99.8%) at 6 months and 95.2% (95% CI, 80.1%-98.9%) at 12 months. The 24-month estimate was identical but was based on few patients at risk and should be interpreted cautiously.

CONCLUSIONS

The double-port DCT approach was technically feasible and was associated with acceptable early clinical and echocardiographic outcomes. Because of the retrospective single-center design, small sample size, absence of a comparator group, and short follow-up, these findings should be interpreted as feasibility data rather than evidence of superiority.

Для цитирования: Elshaer Osama A, Gomaa Mahmoud, Elgamal Ramy M, Fahmy Mohamed S, Dawoud Reda N, Biomy Reda, Ahmed Ahmed M, Salama Mohamed K. Ultrasound Evaluation of Left Ventricular Function in Coronary Artery Ectasia: The Added Value of 2D Speckle-tracking Echocardiography.. Journal of the Saudi Heart Association. 2025. DOI: 10.37616/2212-5043.1457.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.