BACKGROUND

Serum Protein Electrophoresis (SPE) is crucial for the diagnosis and follow-up of monoclonal gammopathy (MG), as it helps to separate and identify these paraproteins. Currently, Pakistan lacks standardized guidelines for SPE reporting and analytical performance. This survey aims to analyze reporting variations from Consultant Chemical Pathologists in Pakistani laboratories.

METHODS

This cross-sectional survey was conducted by the section of Chemical Pathology, Department of Pathology and Laboratory Medicine, at Aga Khan University Hospital, Karachi. A previously validated and published tool was used with some modifications to assess analytical techniques, reporting patterns, and interpretations provided with SPE by different laboratories. Frequency and percentages were calculated for each response and descriptive results were also evaluated. Differences between laboratories were also assessed qualitatively.

RESULTS

Out of the eight laboratories contacted, seven participated in the survey, yielding a response rate of 87.5%. Immunofixation Electrophoresis (IFE) was used by all labs for serum immunotyping. All labs reported a new small abnormal band in patients with no known monoclonal gammopathy or with a known M-protein. Variations were found in terminologies used to label paraprotein, terminologies used to report normal and pathological SPE patterns, electrophoretic technique, methods for quantifying paraprotein in the gamma region on SPE and for albumin quantification. Similarly, the number of decimal places reported, reporting of multiple monoclonal proteins and small paraprotein in the beta region or monoclonal proteins less than 1 g/L, approach for screening, number of fractions reported in gamma region and reporting of interferences were also not standardized and var-iations were noticed.

CONCLUSIONS

Our survey highlighted variations in practices of SPE reporting. These differences in laboratory practices could result in inconsistent test results, which could adversely affect patient care.

Для цитирования: Ahmed Sibtain, Afzal Nayab, Jafri Lena, Khan Mohammad D, Khan Muhammad Q A, Iqbal Sahar, Abbas Ghazanfar, Imran Kiran, Ali Usman, Siddiqui Imran. Reporting Practices of Serum Protein Electrophoresis in Pakistan - a Multicenter Survey.. Clinical laboratory. 2024. DOI: 10.7754/clin.lab.2023.230652.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.